troduction
MetSENS500 meteorological integrated sensor can measure air temperature, air humidity, air pressure, wind speed, wind direction, and output signals of MetSENS500 are SDI-12, RS-485, ModbusRS-485, NMEA RS-232.
METSENS500 weather integrated sensor
METSENS500 weather integrated sensor
Features
Quality measurement
2. Quick and easy installation
3. Compact integrated design
4. Lightweight and sturdy
MetSENS500
Technical Parameters
Temperature Sensor
Measuring range
-40 ~ 70 ℃
measurement accuracy
± 0.3 ℃ (at 20 ℃)
Output resolution
0.1 ℃
Relative humidity sensor
Measuring range
0 ~ 100% RH (at -20 ~ 60 ℃)
measurement accuracy
(At 25 ℃): ± 2% (10 ~ 90% RH)
Output resolution
0.1
Barometric pressure sensor
Measuring range
300 ~ 1100hPa
measurement accuracy
± 0.5hPa
Output resolution
0.1hPa
Wind speed sensor
Measuring range
0.1 ~ 60m / s
measurement accuracy
± 3 (less than 40m / s)
± 5 (40 ~ 60m / s)
Wind speed
0.16 m / s
Output resolution
0.1 m / s
Wind direction sensor
Measuring range
0 ~ 359
measurement accuracy
± 3 (less than 40m / s)
± 5 (40 ~ 60m / s)
Resolution
1
Other technical parameters
Sampling frequency
1Hz
output signal
RS-232, RS-422, RS-485, SDI12, NMEA Modbus
Operating temperature
-40 ~ 70 ℃
Operating Voltage
5 ~ 30VDC
Power consumption
12VDC, 25mA (measurement mode); 0.7mA (power saving mode)
Origin: United States