QT-1050 wave temperature ratio system

Product Details

QT-1050 wave temperature ratio system is a system for studying energy balance (total loss of soil water evaporation and transpiration). Can directly obtain Bowen ratio (B), sensible heat (H) and latent heat (Le) parameters. Farmland ecosystems are located near the ground, and can be divided into soil layers and crop canopies. They are interfacial activity zones that sustain the three-phase material energy cycle conversion. In farmland ecosystems, the energy obtained from the outside world is mainly radiant energy used to expend depletion on farmland evapotranspiration, air heat exchange, heating of the soil, and a very small portion stored as photosynthetic energy. The distribution ratios and rules of net radiant energy in the system have been hot topics in modern farmland ecology, agricultural meteorology, and hydrology.

QT-1050 wave temperature ratio system

The picture is for reference only, the actual order shall prevail.

System composition:

Data collector

Sensors: air temperature and humidity on two profiles, a layer of net radiation, and soil heat flux plates. And can choose other auxiliary weather sensors according to your needs

Solar panels and batteries and other power supply systems

Mounting brackets and accessories

Technical Parameters:

Data collector

Technical Parameters

CR1000

13-bit analog / digital conversion

Analog channels: 8 differential channels (16 single-ended channels)

Pulse channel: 2 pulse channels can record high level (5V square wave), switching value or low level AC signal

Control output: 8 multifunctional digital control ports

Internal temperature compensation, real-time clock

Working temperature: -25 ~ 50 ℃; -55 ~ 85 ℃ (extended)

Data stored in tabular form with time stamps and record labels

When the collector is powered off from the main power supply, the battery supports SRAM memory and clock to ensure that information such as data, programs and accurate time will not be lost

Temperature and humidity sensor

Technical Parameters

SKH 2060

Humidity measurement range: 0 ~ 100%,

Humidity measurement accuracy: less than 2%,

Temperature measurement range: -40 ~ 60 ℃,

Temperature measurement accuracy: ± 0.2 ℃,

Sensor size: diameter: 31mm, height: 152mm

Part number

Technical Parameters

240-100

Spectral range: 0 to 100 microns

Element protection: Teflon coating

Sensitivity: 10 mV / W / m2

Output range: -25 to +25 mV

Measuring range: -2000 to +2000 W / m2

Response time: 20 seconds

Temperature range: -30 ° C to +70 ° C

Part number

Technical Parameters

HFP01

Sensitivity: about 50 µV / W.m-2

Resistance (rated): 2 ohm

Temperature range: -30 ~ 70 ℃

Response time: ± 4 minutes

Measuring range: + 2000 ~ 2000 W.m-2

Temperature dependence: <0.1% / ℃

Origin: United States