QT-1050 wave temperature ratio system is a system for studying energy balance (total loss of soil water evaporation and transpiration). Can directly obtain Bowen ratio (B), sensible heat (H) and latent heat (Le) parameters. Farmland ecosystems are located near the ground, and can be divided into soil layers and crop canopies. They are interfacial activity zones that sustain the three-phase material energy cycle conversion. In farmland ecosystems, the energy obtained from the outside world is mainly radiant energy used to expend depletion on farmland evapotranspiration, air heat exchange, heating of the soil, and a very small portion stored as photosynthetic energy. The distribution ratios and rules of net radiant energy in the system have been hot topics in modern farmland ecology, agricultural meteorology, and hydrology.
QT-1050 wave temperature ratio system
The picture is for reference only, the actual order shall prevail.
System composition:
Data collector
Sensors: air temperature and humidity on two profiles, a layer of net radiation, and soil heat flux plates. And can choose other auxiliary weather sensors according to your needs
Solar panels and batteries and other power supply systems
Mounting brackets and accessories
Technical Parameters:
Data collector
Technical Parameters
CR1000
13-bit analog / digital conversion
Analog channels: 8 differential channels (16 single-ended channels)
Pulse channel: 2 pulse channels can record high level (5V square wave), switching value or low level AC signal
Control output: 8 multifunctional digital control ports
Internal temperature compensation, real-time clock
Working temperature: -25 ~ 50 ℃; -55 ~ 85 ℃ (extended)
Data stored in tabular form with time stamps and record labels
When the collector is powered off from the main power supply, the battery supports SRAM memory and clock to ensure that information such as data, programs and accurate time will not be lost
Temperature and humidity sensor
Technical Parameters
SKH 2060
Humidity measurement range: 0 ~ 100%,
Humidity measurement accuracy: less than 2%,
Temperature measurement range: -40 ~ 60 ℃,
Temperature measurement accuracy: ± 0.2 ℃,
Sensor size: diameter: 31mm, height: 152mm
Part number
Technical Parameters
240-100
Spectral range: 0 to 100 microns
Element protection: Teflon coating
Sensitivity: 10 mV / W / m2
Output range: -25 to +25 mV
Measuring range: -2000 to +2000 W / m2
Response time: 20 seconds
Temperature range: -30 ° C to +70 ° C
Part number
Technical Parameters
HFP01
Sensitivity: about 50 µV / W.m-2
Resistance (rated): 2 ohm
Temperature range: -30 ~ 70 ℃
Response time: ± 4 minutes
Measuring range: + 2000 ~ 2000 W.m-2
Temperature dependence: <0.1% / ℃
Origin: United States