The qua TROLL 200 water level recorder measures and records water level, water pressure, electrical conductivity, and temperature. For ventilated structures, the pressure range can reach 1153 feet (351 meters), and for unvented structures, the pressure range can reach 1120 feet (341 meters). Use the Aqua TROLL 100 to measure and record only conductivity and temperature, and can be deployed at a maximum depth of 500psi (1153ft; 351.43m). The unique conductivity cell design can achieve a wide range and high accuracy measurement in a small diameter instrument. Direct readings via telemetry system and HydroVu data service, or via Rugged Cable (sold separately).
Aqua TROLL 200 Water Level Recorder
Application areas:
Aquifer Reserves and Recovery
Coastal deployments-storm surge analysis for seawater intrusion monitoring, and estuary and wetland research
Remediation Engineering and Mine Water Quality Analysis
Rainstorm monitoring
feature:
Ventilated (measured) or unvented (absolute) pressure measurement
Less than 1 inch in diameter (0.72 inches; 1.83 cm)
Titanium structure
Low energy consumption, when reading every 15 minutes, the typical life of the internal battery is 5 years
Use TROLL® Shield to reduce biological blockage and extend deployment time to more than 6 weeks
External solar power or 8-36V DC power supply.
Full range of conductivity for best accuracy-5 to 100,000 μS / cm
Dynamic density compensation for accurate pressure measurement
Flexible communication protocols (4-20 mA, SDI-12, RS-485)
NIST calibration report guarantees accuracy
Rugged twistlock cable (sold separately)
Technical Specifications:
Aqua TROLL 100 and 200
temperature
Operating temperature:-5-50 ℃ (23-122 ℉)
Storage temperature:-40-65 ℃ (-40 -149 ℉)
Calibration temperature: 0-50 ° C (32-122 ° F)
Aqua TROLL 100 maximum pressure
500 psi (1.153ft, 351.43m)
size and weight
Diameter (OD): 1.83cm (0.72in.) Length: 31.5cm (12.4in.) Weight: 0.5kg (1.0lb)
Texture
Titanium Body and Sensor, Delrin Head Cone, PVC Conductivity Cell
Output options
Modbus / RS485, SDI-1 2, 4 – 20 mA
Battery type & life
3.6 V lithium battery; 5 years or 200,000 readings
External power supply
8-36 VDC
RAM
4.0 MB
data record
190,000
Data log
50
Recording mode
Linear, linear average, event
Fastest recording rate
Linear: 1 time per minute Linear average: 1 time per minute Events: 1 time per second
Fastest output rate
1 time per second
Conductivity sensor type: balanced 4 — electrode conductivity cell
method
EPA Method 120.1; Standard Methods 2510
Range, precision & resolution
Range: 5-100,000 µS / cm
Accuracy: ± 0.5% of reading + 1 µS / cm at readings below 80,000 µS / cm
± 1.0% of reading above 80,000 µS / cm
Resolution: 0.1 µS / cm
Supported parameters
range
unit
Actual conductivity
5-100,000 µS / cm
µS / cm, mS / cm
Specific conductivity
5-100,000 µS / cm
µS / cm, mS / cm
salinity
0-42 PSU
PSU
Total dissolved solids
0-82ppt
ppt, ppm
resistance
10-200000 Ohms-cm
Ohms-cm
Density (salt content of water)
0.98-1.14 g / cm3
g / cm3
Pressure / Water Level / Sensor
Type: Piezoresistive / water level only available on Aqua TROLL 200
range
Absolute pressure (no ventilation)
30 psia: 11 m (35ft)
100 psia: 60 m (197ft)
300 psia: 200 m (658ft)
500 psia: 341 m (1,120ft)
Gauge (Ventilation)
5psig: 3.5 m (11.5ft)
15psig: 11 m (35ft)
30psig: 21 m (69ft)
100psig: 70 m (231ft)
300psig: 210 m (692ft)
500psig: 351 m (1153ft)
Burst pressure
Max 2 x range; burst> 3 x range
Precision & resolution
Accuracy at 15 ℃: Full scale: ± 0.05%
0-50 ℃: full scale: ± 0.1%
Resolution: 0.005% FS or better
Units of measurement
Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O.
Level: in ft mm cm m
Temperature Sensor
method
EPA Method 170.1
Precision & resolution
Accuracy: ± 0.1 ℃ Resolution: 0.01 ℃ or better
Units of measurement
Celsius or Fahrenheit
Origin: United States
Configuration: water level / pressure / conductivity / temperature data logger, Win-Situ 5 software