For this type of fiber optic cable, the optical fiber unit is
positioned in the center, and two parallel strength members
are placed at the two sides, and a steel (stranded) wire as
the additional strength member is also applied, then the
cable is completed with LSZH sheath.
Thanks to its small size and light weight, it is easy to
install this type of fiber optic cable on site.
The strength member of this type of fiber optic cable can be
steel wire, FRP,KFRP, The supporting strength member can be
steel wire or steel stranded wire.
·Small size, light weight, compact construction, easy to
strip without tool for its special groove design, easy to
install.
·Special flexibility design, suitable for indoor cabling,
FTTH(Fiber To The Home) and terminal installation where cable
may be bended repeatedly, especially suitable for last mile
aerial connectivity.
·Optical fiber(s) is palced between two strength members, and
attach an enhanced wire element, with excellent crush and
tensile resistance.
·Excellent anti-bending property when G.657 bending
insensitive fiber is applied, no influence on transmission
loss when the cable is installed at turnings indoors or in
small spaces.
·Flame retardant LSZH jacket for indoor use.
·The strength member can be steel wire, FRP,KFRP, The
supporting strength member can be steel wire or steel
stranded wire.
Optical Characteristics | |||
G.652.D | G.657 | ||
Attenuation | @1310nm | ≤0.40 dB/km | ≤0.36 dB/km |
@1550nm | ≤0.30 dB/km | ≤0.25 dB/km |
Technical Data | ||||
Item | Contents | Value | ||
Fibre Count | 1 | 2 | 4 | |
Self-supporting Strength member |
Material | Steel wire | ||
Diameter(mm) | 1.0mm | |||
Strength member | Material | FRP/Steel wire | ||
Diameter(mm) | 0.5/0.45 | 0.5/0.45 | 0.5/0.45 | |
Sheath | Thickness (mm) | ≥0.40 | ||
Cable diameter(mm) Approx. | 2.0*5.2(±0.1) | 2.0*5.2(±0.1) | 2.0*5.2(±0.1) | |
Cable weight(kg/km) Approx. | 18.5/20 | 19/20.5 | 20/21.5 | |
Operating temperature range(℃) | ‘40- +70 | |||
Tensile strength short/long term(N) | 600/300 | |||
Crush resistance short/long term (N/100mm) | 1000/500 |
Main Performance | |||
Items | Test Standard | Specified Value | Requirements |
Tension | IEC 60794-1-2-E1 | See Technical Data |
Additional attenuation: ≤0.4dB after test |
Crush | IEC 60794-1-2-E3 | See Technical Data |
Additional attenuation: ≤0.4dB after test |
Impact | IEC 60794-1-2-E4 |
R=300mm, 10Nm, one in 3 different places |
Additional attenuation: ≤0.4dB after test |
Repeated Bending | IEC 60794-1-2-E6 | R=30*D |
Additional attenuation: ≤0.4dB after test |
Temperature Cycling | IEC 60794-1-2-F1 | ‘-40℃- +70℃ |
Additional attenuation: ≤0.4dB after test |