MOQ | 2 Metric Ton |
Appearance | Yellow or Brown liquid | pH(1 % aqueous solution ) | 6~9 |
density(25 ℃),g/cm3 | 0.95~1.10 | Compatibility | No precipitation, stratification and turbidity |
Corrosion inhibition rate ,% (80±2 ℃,N80 steel sheet, Dosage 100ppm inflate CO2 4 | ≥72 | Country of Oregin | Henan, China |
Brand | Silong | Sample | 200g provided |
Shelf-time | 1 year |
一. Anti-CO2 corrosion inhibitor HS-01 is a nitrogen-containing five-membered heterocyclic compound, which belongs to adsorption membrane corrosion inhibitor and is oil-soluble and water-dispersible. There are polar and non-polar groups. The polar groups are adsorbed on the metal surface, and the long chain of non-polar groups are aligned from the metal surface to the solvent. On the one hand, corrosion inhibitors change the charge state of metal surface, increase the activation energy of corrosion reaction and make corrosion difficult; on the other hand, non-polar groups are closely arranged on the metal surface to form hydrophobic film, which prevents the charge or material migration related to corrosion reaction and achieves the purpose of inhibiting corrosion.
Perfermance Data:
Perfermance |
Data |
Appearance |
Yellow or Brown liquid |
pH(1 % aqueous solution ) |
6~9 |
density(25 ℃),g/cm3 |
0.95~1.10 |
Compatibility |
No precipitation, stratification and turbidity |
Emulsification tendency |
No emulsification |
Corrosion inhibition rate ,% (80±2 ℃,N80 steel sheet, Dosage 100ppm inflate CO2 40 min) |
≥72 |
二、Scope and method of application
1. The corrosion inhibitor is used to control the corrosion of oil and gas wells, gathering pipelines and sewage treatment systems. It has good inhibition on CO2 corrosion, good compatibility with inorganic salts and polymers, and no damage to formation.
2. The product can effectively control the corrosion caused by carbon dioxide and minerals.
3. The product can synthesize a variety of corrosion inhibitors based on different types of amines, alcohols, ethers, phosphides and sulfides according to the use temperature and medium.
4. Because of the pertinence of the technology, the effect of block management and system anti-corrosion is better.
5. Construction safety and pollution-free
6. The operation of annulus or endpoint dosing is simple. The dosing concentration is 100-200 ppm, which can be adjusted according to the specific situation.
三、Major economic indicators:
①Reduction of corrosion rate②decrease of total iron index③decrease of number of laying wells due to corrosion.
四、Transport and storage
The product is packed in plastic drums with a net content of 25 kg or 200 kg. It can also be packed according to user's requirements.
This product should be transported according to the routine chemical products, not forced impact; products should be placed in ventilated, cool and dry warehouses, away from fire sources. The product is valid for one year.
800 meters west of the intersection of Petrochemical Road and Pushui Road