Please wait while your account is being registered at Tradewheel.com Loading Spinner

Join World's Fastest Growing B2B Network

Insertion Working Condition Flowmeter with Calibration

MOQ1 Piece
PortNanjing
Lead Time21

Product Details

Based on the principle of differential pressure measurement, the smart insertion working condition flowmeters are divided into single-point and multi-point insertion ones. Using the smart insertion working condition flowmeter based on the analysis of computational fluid dynamics, the flow field distribution status (temperature field, velocity field, pressure field, humidity field, concentration field, etc.) of the flowing medium in the tube can be learned. Vortex, backflow and transition, etc. can be avoided as the working condition flowmeters are installed at a relatively stable position in the flow field to improve the repeatability and linearity of the flowmeter. Through the fluid analysis of the pipe network structure parameters and medium operating parameters under actual working conditions, the measurement accuracy of the condition (not the laboratory accuracy of the calibration unit under the sufficient condition of the straight pipe section) and the corresponding flow calculation formula (which can be completed by the working condition calibrator) can be obtained to measure the flow in the pipeline in a stable and accurate way.

Compared with the uniform-velocity tubes, the smart insertion working condition flowmeters boast the following advantages:

l  The maintenance amount of on-site metering can be reduced because of the optimization of the pressure measurement points and the structure of the pressure tapping.

l  High-accuracy wide-range measurement: From measurement range, the accuracy hovers around 0.5%~2.0%, and the automation is guaranteed.

l  Technology to increase differential pressure through mechanical design: The differential pressure value is relatively high at small flow rates, improving metering accuracy.

l  Compared with the traditional insertion uniform velocity tubes, the function of reverse purge of the smart insertion working condition flowmeter ensures no pressure relief.

l  Online installation: It can be installed online without stopping production.

l  Applicable to pipes whose diameters are ≥DN200.

l  Applicable medium: gas, liquid, and medium- and low-pressure steam.

l  Configuration: If used with working condition calibrator, the flowmeters could work more effectively.

Register Your Company