Gold Multimeter Tan Delta Capacitance and Dissipation Factor Test Set Dielectric Loss Meter

FOB Price 100 - 1200 USD / 1
MOQ1 1
Portshanghai/chongqing/guangzhou/ningbo
PackagingWooden box with foam inside;
Lead Time3~5days

Quick Details (View All)

Product nameTan Delta Capacitance and Dissipation Factor Test Set ApplicationGold Multimeter
FunctionDielectric Loss Meter Use conditions-15℃-40℃ RH<80%
Anti-interferenceFrequency conversion PowerAC 220V±10%
Self-excited powerAC 0V-50V/15A

Product Details

tan delta12.jpg

Principle of Tan Delta Test
A pure insulator when is connected across line and earth, it behaves as a capacitor. In an ideal insulator, as the insulating material which acts as dielectric too, is 100 % pure, the electric current passing through the insulator, only have capacitive component. There is no resistive component of the current, flowing from line to earth through insulator as in ideal insulating material, there is zero percent impurity.


In pure capacitor, the capacitive electric current leads the applied voltage by 90°.

In practice, the insulator cannot be made 100% pure. Also due to the aging of insulators, the impurities like dirt and moisture enter into it. These impurities provide the conductive path to the current. Consequently, an electric leakage current flowing from line to earth through the insulator has a resistive component.

Hence, it is needless to say that, for good insulator, this resistive component of electric leakage current is quite low. In another way, the healthiness of an electrical insulator can be determined by the ratio of the resistive component to the capacitive component. For good insulator, this ratio would be quite low. This ratio is commonly known as tanδ or tan delta. Sometimes it is also referred to as dissipation factor.

JYC has anti interference fuction by frequency conversion during insulation loss testing, and it is not necessary to change wire as CVT testing, and same time JYC can test the turn radio of CVT.

Technical Parameters

Item Name

GDGS

Automatic Transformer Oil Tan Delta Tester

Condition of Use

-5℃-40℃ RH<80%

Power Source

AC 220V±10% Without Frequency Limit

AC High Voltage Output

400V-2200V ±2% Every 100V 50VA

DC High Voltage Output

00V-2200V ±2%

Temperature Control Induction Stove

Maximal Power 500W

Temperature Control Range

<100℃

Temperature Measuring Error

±0.5℃

Control Temperature Error

0.1℃

Control Temperature Time

Room Temperature 90℃ <20min

Measuring Range

tgδ Without Limit
Cx 15PF-300PF
Rx 10M-10T

Resolution

tgδ 0.001%
Cx 0.01pF
Rx 0.01

Precision

delta tgδ:±(Reading*0.5%+0.020%)
delta Cx :±(Reading*0.5%+0.5PF)
delta Rx :±Reading * 10%

Relative Dielectric Loss Constant

Εr Calculated Automatically

Volume Resistivity

ρ Calculated Automatically

Dimension

450(L)×310(W)×360(H)

Net Weight

21KG

Transformer Capacity Characteristics Tester Function

  • We can measure a variety of distribution transformer, power transformer capacity instead of the additional power. It is more convenient and efficient.
  • Combined with the power, voltage, boost up flow and other equipment, it measures various transformer no-load current, no-load loss, impedance voltage, load loss and so on.
  • All results are automatically carried out relevant correction. You only need to input the related parameters (such as temperature, load adjustment coefficients), then the instrument can automatically correct such as waveform deformity correction, temperature correction, correction of non rated voltage, rated current correction.
  • The maximum voltage is up to 750V and the maximum current is up to 100A. It is equipped with protection circuit.
  • The voltage and current range can be very flexible and easy to expand.
  • It has large screen, high brightness LCD display, English menu and operation tips, friendly man-machine interface and wide temperature, brightness adjustable type LCD screen, which can adapt to the different temperature.
  • According to the test results of no-load and load loss, it can automatic presume the three-phase oil immersed distribution transformer and power transformer’s performance levels as the reference (this instrument is currently only available for three-phase oil immersed transformer and power transformer performance level code. Others are invalid.
Detailed Images

tan delta5.jpgtan delta10.jpgtan delta6.jpgtan delta7.jpgtan delta2.jpgtan delta1.jpg

Company Information

1.png

Chongqing Gold Mechanical&Electrical Equipment Co.,Ltd was founded in 2008. We have a strong team including top sales, skilled engineers and we have our own manufacture with high quality. we mainly design and manufacture the Transformer Tester, Circuit Breaker Analyzer, CT PT Analyzer, Hipot Tester , Relay Tester and so on for more than 10 years.

After several years’ development, our products have become high intelligent and wide coverage. And our company has become one of the leading manufacturer of oil purifier and electrical testing equipment in China;

We have developed sales channels in many countries such as UAE, Saudi Arabia, Malaysia, Thailand, Pakistan, India, Germany, Belgium, USA, Mexico, Kenya, Nigeria, South Africa and other countries worldwide.
And we have gained strong advantage and high reputation in international market.

Certificates:

.jpg

Exhibitions:

1.jpg

Contact

.jpg

Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd.
Mobile: +86 151 2302 9823

Email:

WhatsApp/Skype:+86 151 2302 9823
Tel:86-23-62613622
Fax:86-23-62940030

Website:www.cqgoldequipment.com Add:25F, Huarun Center, Xiejiawan Street, Jiulongpo District, Chongqing, China, 400050

Click Send for more information!

Register Your Company