Please wait while your account is being registered at Tradewheel.com Loading Spinner

Join World's Fastest Growing B2B Network

vlf ac hipot tester vlf cable testing equipment

FOB Price 100 - 2000 USD / 1
MOQ1 1
Portshanghai/chongqing/guangzhou/ningbo
PackagingWooden box with foam inside;
Lead Time3~5days

Quick Details (View All)

Functionac vlf high voltage generator PowerAC50Hz, 220V ±5%
Humidity≤ 85%RH Use conditionindoor and outdoor; temperature: -10℃+40℃
Voltage wave form distortion≤ 5% Output rated voltage30/50/80KV
Output frequency0.1Hz,0.05Hz,0.02Hz

Product Details

vlf tester23

What is a Very Low Frequency Withstand Test?

A Very Low Frequency (VLF) Withstand Test is an AC Withstand Test usually carried out at a frequency between 0.1 Hz and 0.01 Hz. This sino kind of test is suited for testing high capacitance loads such as cable and rotating machinery. This is a pass fail test i.e. bad cable will fail during testing rather than in service and other test instruments.

vlf ac hipot tester vlf cable testing equipment

The VLF test surveying instruments can be used in a number of ways:

  • Apply VLF to cables in a simple withstand approach to detect potential failures (faults) in the cable insulation during a planned outage. The tested cable must withstand an AC voltage for a specified testing time without flashover. This method yields a "pass/fail" statement. VLF cable testing uses different wave shapes, typically sine and square and care must be taken when describing the voltage to be used. RMS and peak voltages have different relationships to each other depending on the wave shape and IEEE 400.2 uses the peak voltage level to equate the wave shapes. Frequency ranges used are within the range of 0.01 Hz to 0.1 Hz, where frequency selection depends on the load presented by the cable. Test voltage levels are either calculated using a multiple of the cable's nominal phase-phase voltage or via tables in IEEE 400.2; typically they are in the range of 1.5 U0 to 3 U0. The VLF cable testing time varies from 15 to 60 minutes. IEEE 400.2 establishes some suggested test voltages and times. Subsequent work by the CDFI has shown there to be no significant change in the efficacy of a VLF test conducted over the frequency range 0.1 to 0.01 Hz when the IEEE 400.2 voltages and times are used.
  • Apply VLF to cables in a monitored withstand approach where a diagnostic measurement is made before and during the course of the withstand test. Monitoring a diagnostic enables some additional decision making before the final test voltage is reached. Some cables are not good candidates for withstand testing surveying and a diagnostic indication obtained at a lower voltage can negate the need to perform withstand testing. During the test measurement of a diagnostic parameter can be used to optimise test times. Test times can be shortened for cables with good diagnostic indications or lengthened for cables that show deteriorating diagnostic measurements during the test.
  • Apply VLF to measure insulation losses (i.e. the insulation dissipation factor or Tan-delta). In this case, the IEEE 400.2 establishes the criteria for assessment. The test is typically performed over a range of test voltages from 0.5 Uo to 2 Uo depending on the standard/guide that is being followed.
  • Apply VLF in order to detect and measure partial discharge. In this case, the IEEE 400.3 outlines a procedure for assessment and IEC 60270 provides the background for partial discharge testing of high voltage apparatus. The test is typically performed over a range of test voltages to identify and surveying the different defects and their inception and extinction voltages .

vlf hipot testervlf cable testervlf ac hipot tester vlf cable testing equipment

vlf tester21vlf8

vlf ac hipot tester vlf cable testing equipment

VLF HV Tester Series

Model no

Rated Voltage

Load Carrying

Capacity

Power

FuseTube

Product Structure

VLF-30

30kV

(Peak)

0.1Hz,≤1.1µF

10A

Controller

Booster

0.05Hz,≤2.2µF

0.02Hz,≤5.5µF

VLF-40

40kV

(Peak)

0.1Hz,≤1.1µF

10A

Controller

Booster

0.05Hz,≤2.2µF

0.02Hz,≤5.5µF

VLF-50

50kV

(Peak)

0.1Hz,≤1.1µF

20A

Controller

Booster

0.05Hz,≤2.2µF

0.02Hz,≤5.5µF

VLF-60

60kV

(Peak)

0.1Hz,≤0.5µF

20A

Controller

Booster

0.05Hz,≤1µF

0.02Hz,≤2.5µF

VLF-80

80kV

(Peak)

0.1Hz,≤0.5µF

20A

Controller

Booster

0.05Hz,≤1µF

0.02Hz,≤2.5µF

VLF-90

90kV

(Peak)

0.1Hz,≤1.1µF

20A

Controller

Booster

0.05Hz,≤2.2µF

0.02Hz,≤5.5µF

Packaging & Shipping

vlf ac hipot tester vlf cable testing equipment

pack5.jpg

Company Information

1.png

Chongqing Gold Mechanical&Electrical Equipment Co.,Ltd was founded in 2008. We have a strong team including top sales, skilled engineers and we have our own manufacture with high quality. we mainly design and manufacture the Transformer Tester, Circuit Breaker Analyzer, CT PT Analyzer, Hipot Tester , Relay Tester and so on for more than 10 years.

After several years’ development, our products have become high intelligent and wide coverage. And our company has become one of the leading manufacturer of oil purifier and electrical testing equipment in China;

We have developed sales channels in many countries such as UAE, Saudi Arabia, Malaysia, Thailand, Pakistan, India, Germany, Belgium, USA, Mexico, Kenya, Nigeria, South Africa and other countries worldwide.
And we have gained strong advantage and high reputation in international market.

Certificates:

.jpg

Exhibitions:

1.jpg

Contact

.jpg

Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd.
Mobile: +86 151 2302 9823

Email:

WhatsApp/Skype:+86 151 2302 9823
Tel:86-23-62613622
Fax:86-23-62940030

Website:www.cqgoldequipment.com Add:25F, Huarun Center, Xiejiawan Street, Jiulongpo District, Chongqing, China, 400050

Click Send for more information!

Register Your Company