MOQ | 1 Unit |
Packaging | 480mm*245mm*490mm |
Lead Time | 7 |
Frequency | 20Hz-200kHz | Warranty | 12 months |
OEM | available |
UC2869XB/UC2867XB/UC2866XB/UC2878XB 20/24PIN Transformer Tester
Performance Characteristics
■ 7 inch 16: 9 TFT LCD display, resolution: 800×480 RGB
■ All the test results are shown in one page without turning to other pages
■ It is more convenient for U disk to directly save the test results,
■ Maximum test frequency is 1MHZ , resolution is 10 mHz.
■ Basic measurement accuracy is 0.05%,the ultra-fast test mode is increased (150 times / Sec)
■ Automatic level control ALC function for testing voltage or current
■ 30 Ω, 100 Ω, 10 /100, 10 /CC, four different signal sources’ output impedance.
■ Built-in comparator, 10 files sorting and file counting function
■ Internal 100 setting files are used to save or call, testing files of U disk are unlimitedly expanded to save or call.
■ Optional ±10V(±100mA) and 1 A internal DC bias source.
■ Software version of the instrument can be upgraded and updated by USB HOST.
■ U disk supports the file systems with FAT16, FAT32 format.
■ Standard RS232C、HANDLER、USB HOST,optional GPIB、LAN interface.
Measurement function |
|||
Test frequency |
UC2869XB 20 Hz-200 kHz,10mHZ resolution UC2867XB 20 HZ - 300 kHZ, 10mHZ resolution UC2866XB 20 HZ - 500 kHZ, 10mHZ resolution UC2878XB 20 HZ - 1M HZ, 10mHZ resolution |
||
Test parameters |
|Laps ratio, lap, phase, inductance, capacitance, leakage inductance, quality factor, AC resistance, DC resistance, balance, pin short circuit; LED test |
||
Basic measurement accuracy |
0.05% |
||
Equivalent Circuit |
Series, parallel |
||
Math function |
absolute deviation, percentage deviation |
||
Range method |
automatic, hold, manual selection |
||
Trigger mode |
internal, manual, external, bus |
||
Measurement speed(≥1kHz) |
Fast speed: 50 times/sec, medium speed: 12 times/sec, slow speed: 3 times/sec |
||
Average time |
1—255 |
||
Delay time |
0—60s, 1ms as step |
||
Correction function |
Open circuit / short circuit / load |
||
Test end configuration |
Five ends |
||
List scan |
10 points list scan function |
||
Display mode |
Direct reading,Δ,Δ%,V/I(Measured voltage / current monitoring) |
||
Display |
800×480 RGB7 inch 16: 9 TFT LCD display |
||
Test signal |
|||
Output impedance |
30 Ω, 100 Ω, 50Ω, 10 /CC optional |
||
Test signal level |
Normal:5mV-2V, 1mV step constant level:10mV-1V, 1mV step |
||
Bias source |
internal |
0V, 1.5V, 2V |
|
optional |
UC6802A:±10V(±100mA)DC bias current |
||
UC6802B:0-1A DC bias current |
|||
Display range |
|||
|Z|, R, X |
0.01m Ω — 99.9999 MΩ |
||
DCR |
0.01 mΩ — 99.9999 MΩ |
||
|Y|, G, B |
0.00001µS — 99.9999 S |
||
C |
0.00001 pF — 9.9999 F |
||
L |
0.00001 µH — 9999.99 H |
||
D |
0.00001 — 9.9999 |
||
Q |
0.00001 — 9999.9 |
||
θ (DEG) |
-179.999º — 179.999 º |
||
θ (RAD) |
-3.14159 — 3.14159 |
||
Others |
|||
Comparator function |
Ten files: (nine files qualified, a file unqualified), and another subsidiary file AUX |
||
Memory |
10 groups of internal setting files for storage / recall |
||
Interface |
Standard RS232C, HANDLER, USB HOST, headphone interface, optional GPIB, LAN interface |
No.79 Lihua North Road, Tianning District, Changzhou, Jiangsu, China