Model
|
AJBLP3000S
|
Output
|
Rated Power
|
3000W
|
3000W
|
AC Voltage
|
220/230/240V(adjustable in menu)
|
220/230/240V(adjustable in menu)
|
Frequency
|
50Hz/60Hz(adjustable in menu)
|
50Hz/60Hz(adjustable in menu)
|
Continuous Power
|
2700W
|
3000W
|
Wave Form
|
Pure Sine Wave
|
THD
|
5%
|
Input
|
Battery voltage
|
12V
|
24V
|
Votage range
|
9V-17V
|
18V-31V
|
DC current
|
291A
|
144A
|
No load current
|
2A
|
1.1A
|
Standby current
|
15mA
|
13mA
|
Efficiency
|
90%
|
91%
|
Battery type
|
Lithium Battery / Lead Acid Battery
|
Battery
Input
Protect
|
Fuse
|
400A*1
|
200A*1
|
Battery low voltage alarm
|
9.5/10/10.5/11/11.5/12/12.5V, Buzzer alarm, E06 in LED
monitor
|
19/20/21/22/23/24/25V, Buzzer alarm, E06 in LED monitor
|
Recovery of battery low voltage alarm
|
10/10.5/11/11.5/12/12.5/13
|
20/21/22/23/24/25/26V
|
Low voltage alarm protect
|
9/9.5/10/10.5/11/11.5/12V(adjustable ), E01 in LED monitor,
inverter will turn off automatically in 30s.
|
18/19/20/21/22/23/24V(adjustable ), E01 in LED monitor,
inverter will turn off automatically in 30s.
|
Recovery of low voltage alarm protect
|
Recovery in 30s: 11/11.5/12/12.5/13/13.5/14V
|
Recovery in 30s: 22/23/24/25/269/27/28V
|
High voltage protect
|
17V, E02 in LED monitor, inverter will turn off
automatically in 30s.
|
32V, E02 in LED monitor, inverter will turn off
automatically in 30s.
|
Recovery of high voltage protect
|
Recovery in 30s: 16.5V
|
Recovery in 30s: 31V
|
Output
Protect
|
High temperature alarm
|
Buzzer alarm, E07 in LED monitor
|
Buzzer alarm, E07 in LED monitor
|
Over temperature
|
Housing temperature 65ºC
|
Housing temperature 65ºC
|
Buzzer alarm, inverter stops working with E04 in LED
monitor, recovery after temperature reduction.
|
Buzzer alarm, inverter stops working with E04 in LED
monitor, recovery after temperature reduction.
|
Short circuit
|
Short circuit protect is
locked, buzzer alarm, E03 in LED
monitor, inverter will turn off
automatically in 30S.
|
Short circuit protect is
locked, buzzer alarm, E03 in LED
monitor, inverter will turn off
automatically in 30S.
|
Load alarm
|
<11.4V,
1100±200W
11.4<V<11.8,
1200±200W
>11.8V, 1300±200W
Buzzer alarm, E08 in LED monitor
|
<22.8V,
1100±200W
22.8<V<23.6,
1200±200W
>23.6V,
1300±200W
Buzzer alarm, E08 in LED
monitor
|
Recovery of load alarm
|
<11.4V,
1000±200W
11.4<V<11.8,
1100±200W
>11.8V,
1200±200W
|
<22.8V,
1000±200W
22.8<V<23.6,1100±200W
>23.6V,
1200±200W
|
Over load
|
<11.4V,
1000±200W
11.4<V<11.8,
1100±200W
>11.8V,
1200±200W
|
<22.8V,
1000±200W
22.8<V<23.6,1100±200W
>23.6V,
1200±200W
|
The output will be shutdown
and
locked in 300ms in case of
loading
over 4000w (the output will
be
shutdown and locked in 30s
when
loading is less than 4000w).
buzzer
alarm, E03 in LED monitor,
inverter
will turn off automatically in
30S
|
The output will be shutdown
and
locked in 300ms in case of
loading
over 4000w (the output will
be
shutdown and locked in 30s
when
loading is less than 4000w).
buzzer
alarm, E03 in LED monitor,
inverter
will turn off automatically in
30S
|
USB
|
Output voltage
|
5V
|
Output current
|
2.1A
|
Environment
|
Working Temperature
|
-20ºC-+40ºC
|
Working Humidity
|
10-90%RH
|
Storage Temperature/Humidity
|
-30ºC-+70ºC,10-95%RH
|
Physical Parameters
|
Weight
|
N.W.: 6.44kg
|
Size
|
517*209*110mm(L*W*H)
|
Package Size
|
530*430*120mm(L*W*H)
|
Remark
|
All the
diameters are measured under normal voltage 12V/24V, in
working temperature 25ºC
Menu setting,
Fe: Frequency
setting
Lv: Battery low voltage protect
setting
Out: Output voltage
setting.
Al: Buzzer alarm
setting
In: Working mode
setting
(In1: normal working mode/ In2:
power-saving mode/ In3: auto-shutdown mode in 30 minutes
without load)
'VBAT':DC input voltage
'VINV':Inverter output
voltage
'Power': Inverer output
power
'Err': Error or alarm in inverter, error
code details can be checked in the digital LCD
display
E01: Battery low
voltage protect
E02: Battery high
voltage protect
E03: Inverter
output short circuit protect
E04: Inverter over
temperature protect
E05: Inverter over
load protect
E06: Battery low
voltage alarm
E07: Inverter over
temperature alarm
E08:
Over load
alarm
E09: Inverter
output over voltage protect
Remote
controller:
'ENERGY':Battery capacity
'Power': Inverter output power
percentage
'OVP': Over voltage
protect
'OTP': Over temperature
protect
'Normal
: Inverter in normal
working status
'SCP': Short circuit
protect
'OLP': Over load
protect
'LVA': Low voltage
alarm
'LVP': Low voltage
protect
|