Place of Origin | United States | Brand Name | Teledyne |
Model Number | C06689-B3 | Application | Industrial Automatic |
Working Voltage | 10-30V/5V/8V |
Teledyne oxygen sensor C06689-B3 ,B-3
C06689-A2C A-2C
C06689-A5 A-5
C06689-B1 B-1
C06689-B2C B-2C
C06689-B2CXL B-2CXL
C06689-B3 B-3
C06689-L2C L-2C
C06689-L2CL L-2CL
C06689-Z2C Z-2C
C06689-E2 E-2
B71875 INSTA TRACE
B73106 INSTA TRACE CO2
3000MA
3010MA
3110(311D)
311TC
3000TA
311
311XL
311TCXL
311PC
3190
320P
3010PAC
4020
8800A
INSTATRANS 3001
INSTATRANS-XD
3290
A-2C
L-2C
B-2CXL
A-5
B-2C
B-37937
UFO-130-2
C73870
C65098A
D67472REV8
GB300
INSTA TRACE (B71875)
Application overview
RANGE |
BACKGROUND GAS |
TELEDYNE INSTRUMENTS |
SENSOR OPTIONS |
Trace |
Less than 1000 ppm CO2 in the background gas |
311, 316, 317, 318, 3160 |
B-2C |
3000T series |
L-2C |
||
More than 1000 ppm up to 100% CO2 in the background gas |
All trace oxygen instruments |
A-2C |
|
Note: To use the A-2C or B-2C sensor in a 3000T series instrument, adapter part number B66378 is required. |
|||
Note: The L-2C sensor cannot be used in our older analog models (300 series). |
|||
Percent |
Less than 1000 ppm CO2 in the background gas |
311P, 320A / P / BRC, 326, 327, 328 |
B-1, B-3 standard; |
More than 1000 ppm up to 100% CO2 in the background gas |
A-5 |
A-5 |
C6689-A5 |
Intermittent or continuous monitoring of percent O2 in gas mixtures containing 0-100% CO2. 90% response is time is 45 seconds. |
Has more tolerance to exposure to air than A-3. No restrictions on CO2 concentration. |
B-1 |
C6689-B1 |
General purpose percent oxygen analysis where fast response is desired (90% in less than 7 seconds). |
Use B-3 or C-3 where longer life is required and response time is relatively unimportant. May be used to spot check flue gas. |
B-2C |
C6689-B2C |
General purpose trace O2 analysis for use in inert gas and hydrocarbon streams. Low range limit is 0-10 ppm. |
May be used in CO2 free gas streams containing highly mobile gases such as H2, He and ethylene. |
INSTA TRACE |
B71875 |
Special patented construction provides rapid recovery, during initial cell installation, to low PPM levels by reducing the recovery period from several hours to just minutes. Low range limit is 0-10 ppm. |
Used for trace O2 analysis in inert gas and hydrocarbon streams. |
B-2CXL |
C6689-B2CXL |
Specially qualified B-2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm. |
May be used in CO2 free gas streams containing highly mobile gases such as H2, He and ethylene. |
B-3 |
C6689-B3 |
Percent O2 analysis, best compromise between long life and fast response. |
May be used to spot check flue gas. |
B-4C |
C14613-B4C |
Trace O2 cell specifically designed for the Model 317EXI. |
Same performance as the B-2. |
B-5 |
C45091-B5 |
Special application cell (non-standard) where long life and moderately fast response are required; B-5 has a factor of 3x the life of a B-3. |
Requires 3x the amplifier gain of the B-3. Expected life is 36 months in air. |