MOQ | 1 Set/Sets |
Condition | New | Place of Origin | Henan, China |
Type | Resistance Furnace | Usage | Heat Treatment Furnace |
Brand Name | SUTONG | Voltage | AC,3-phase,400V±10%,50/60Hz |
Dimension(L*W*H) | 204X216X242CM | Certification | ISO;CE |
Warranty | 1 Year | After-sales Service Provided | Field maintenance and repair service, Video technical support, Online support |
Product Name | Metal heat treatment furnace | Application | Nitriding, Carburizing, Carbonitriding, Bright annealing |
Feature | PLC control/Atmosphere protection/multi-function | Heating element | 0Cr25Al5 alloy resistance band |
Heating time | ≤3 hours (from room temeprature up to 950.C) | Load capacity | 350Kg |
maximum temperature | 1000.C | Chamber material | Cr25Ni20 stainless steel |
Furnace temperature uniformity | ±5.C (at 950.C) | Input voltage | AC,3-phase,400V±10%,50 or 60Hz |
Power | 75KW | Weight | 3.25 tons |
RX3-75/10 box type heat treatment resistance furnace
A. Overview
This series of box-type heat treatment furnace is a periodic operation heat treatment equipment, which chamber's maximum temperature can reach 1000 ℃, and can continuously work at 950℃ or lower temperature.The furnace heating chamber wall is embedded in stainless steel plate, to ensure the cleaning of heating room cleaning and no pollution to the processed workpieces. The material frame is made of stainless steel and layered stainless steel wire mesh inside. In this way, both the small workpiece can be loaded in the material frame, and the protective gas can be successfully passed through the surface of workpieces to be processed, and more convenient for loading and discharging workpieces.
This furnace uses PLC controller to realize the automatic operation of the heat treatment process, such as door opening / closing, inert gas input, over-temperature alarm, overpressure in the box, power over-current(over load) protection and etc.
B. Function
This furnace is used for nitriding ,carburizing, or carbonitriding, as well as bright annealing and other heat treatment of the metal parts in protective gases .
E. List of common models and technical parameters of RX3 series furnace
Item |
Unit |
technical parameters |
|||
Model |
|
RX3-30/10 |
RX3-45/10 |
RX3-60/10 |
RX3-75/10 |
Rated power |
KW |
30 |
45 |
60 |
75 |
Rated voltage |
V |
400±10%,or 600V±10% |
400±10%,or 600V±10% |
400±10%,or 600V±10% |
400±10%,or 600V±10% |
Phase |
|
3 |
3 |
3 |
3 |
Connect method |
|
Y |
Y |
Y |
Y-Y |
Max. temp |
℃ |
950 |
950 |
1000 |
1000 |
Non-load power loss |
KW |
≤7 |
≤9 |
≤12 |
≤15 |
Max. capacity |
Kg/h |
125 |
200 |
275 |
350 |
Heat chamber size(L×W×H) |
cm |
95×45×35 |
120×60×45 |
120×80×60 |
120×100×100 |
Heating time (from room temp. To max. Temp.) |
h |
≤2 |
≤2 |
≤3 |
≤3 |