Quantity | 5 - 100000 |
Price | 10000000 |
Packaging | Box |
Lead Time | 7 days |
Orange | blue |
1、 Product Overview
The ZKHH-180 pressure transmitter uses sputtering thin film sensors, imported silicon diffusion sensors, and ceramic pressure sensors as sensitive components. It adopts dedicated integrated modules and achieves accurate measurement and transmission of pressure changes in media such as liquid level, gas, and steam through precise temperature drift, zero point, and nonlinear compensation. Ideal monitoring of pressure vacuum in various places such as industrial and mining enterprises, research institutes, and other departments.
2、 Product Usage:
Industrial on-site process pressure control, aerospace industry, petrochemical industry.
Instruments, medical and food industries, navigation and shipbuilding industries, water conservancy, hydropower, power plants, etc.
3、 Performance parameters:
Measurement medium Gas, liquid, oil, and other media compatible with 316
Measurement form and range: gauge pressure (G) - large (0-60) MPa, small (0-0.5) KPa
Absolute pressure (A) - large (0-40) MPa, small (0-5) KPa
Negative pressure (B) - (-0.1~40) MPa, small (-0.2~0.2) KPa
Accuracy levels 0.1, 0.25, 0.5
2-5 times the overload capacity range
Long term stability less than 0.25% FS/year, less than 0.5% FS/year
Power supply 15-36 VDC (rated voltage 24VDC)
Output signal (4-20) mA (two/three wire system), (0-10/20) mA
(0-5) V, (1-5) V, (0-10) V
Display method: pointer or digital display is optional
Calibration achieves zero and span adjustment by adjusting the potentiometer
Working temperature: (-40~80) ℃ Compensation temperature: (-20~70) ℃
Working temperature -40~80 ℃ Compensation temperature: -20~70 ℃
Process connection M20 × 1.5 External thread( Ф 3 inner holes) or specified by the user
Isolation diaphragm material 316 stainless steel
Sensor interface material 1Cr18Ni9Ti
Shell material alloy aluminum
Protection level IP65
4、 Product model
Product selection: ZKHH-180 port E port A port C port D port F port industrial pressure transmitter
Mouth range (indicate pressure range)
G. Gauge pressure A, positive pressure B, sealing pressure C, negative pressure
Port diaphragm material
K. Diffusion Silicon (default) T, Ceramic Piezoresistive P, Ceramic Capacitor Y - Sputtered Thin Film High Precision Chip
E-port output signal
1. (0-5) VDC 2. Two wire system (4-20) mA (default) 3. (0-10) mA 4. Other indications
A-port accuracy
1. 0.1 2, 0.25 3, 0.5
C port process connection method
1. External thread M20 × 1.5 (default) 2. External thread G1/2 3. External thread NPT1/2 4, M27 × 2 (flush membrane standard interface 5, flange fixation 6, other indications
D-port display mode
1. No display (default) 2. 0-100% linear indication 3. LC