Lead Time | 6+ months |
The test medium used is water-glycol mixture or pure glycol
(for example Glysantin® G40, G44, G48). The refrigeration cycle
is tested in the temperature range from -40 to +20 degrees
Celsius, and in the heating circuit from +20 to +140 degrees
Celsius. The development of alcohol-containing vapors (danger
of explosion) is avoided by means of specially-developed
closed-circuit test equipment with the help of pressure.
Optionally, an additional air-conditioning chamber can also be
used to generate environmental simulation.
The volume flow of the test medium can vary from 3 to 30 l/min
at a pressure of 0.2 to 10 bar (max 12 bar). The load changes
are freely programmable with sinusoidal or trapezoidal rise in
a test frequency of 0.2 to 1 Hz. The test system can be used to
test complete systems as well as individual assemblies made of
various plastics, metals and sealants. With the aid of
realistic simulation, the weak points in the material composite
are precisely determined – for example in the area of a weld
seam – and can be optimized early in the development process.
Performance: