Product name | Tan Delta Test Kit Manufacturers | Application | Partial Discharge Detector |
Function | Insulation Power Factor Tester | Measuring duration | About 40s, depending on measuring method |
Input power | 180V ~ 270VAC, 50Hz ± 1% | Computer interface | Standard RS232 interface |
Pinter | mini-type thermal printer |
Introduction of Partial Discharge Detector Insulation Power Factor Tester Tan Delta Test Kit Manufacturers
Dielectric loss/power factor measurement on power transformers (Tan Delta)
The insulation state is very important for the safe and reliable operation of the transformer. Measuring the capacitance and dissipation factor/power factor of the insulation helps to determine the insulation state between the bushing or winding.
For example, a change in capacitance indicates a mechanical displacement of the winding or a local breakdown in the bushing. The aging and deterioration of the insulation, coupled with the ingress of moisture, increase the total amount of electrical energy converted into heat in the insulation. These energy loss rates are measured as dielectric loss factors.
Through our test system, the capacitance and dielectric loss factor/power factor can be measured through variable frequency signals. In this way, the aging phenomenon can be detected early, and corresponding measures can be taken to deal with it, such as repair, oil treatment or drying.
Features of Partial Discharge Detector Insulation Power Factor Tester Tan Delta Test Kit Manufacturers
No. |
Item Name |
GDGS Automatic Transformer Power Factor Tester |
||||
1 |
Use conditions |
-15℃-40℃ |
RH<80% |
|||
2 |
Anti-interference |
Frequency conversion |
||||
3 |
Power |
AC 220V±10% |
||||
4 |
High output |
0.5KV-10KV |
Every 0.1kV |
|||
Precision |
2% |
|||||
Maximum current |
200mA |
|||||
Capacity |
2000VA |
|||||
5 |
Self-excited power |
AC 0V-50V/15A |
45HZ/55HZ 47.5HZ/52.5HZ 55HZ/65HZ 57.5HZ/62.5HZ Automatic double frequency |
|||
6 |
Resolving power |
tgδ: 0.001% |
Cx: 0.001pF |
|||
7 |
Precision |
tgδ:±(Reading*1.0%+0.040%) |
||||
C x :±(Reading*1.0%+1.00PF) |
||||||
8 |
measuring range |
tgδ |
Unlimited |
|||
C x |
15pF < Cx < 300nF |
|||||
10KV |
Cx < 60 nF |
|||||
5KV |
Cx < 150 nF |
|||||
1KV |
Cx < 300 nF |
|||||
CVT test |
Cx < 300 nF |
|||||
9 |
CVT range |
10-10000 |
||||
accuracy |
0.1% |
Resolving power |
0.01 |
|||
10 |
Exterior dimension |
350(L)×270(W)×270(H) |
||||
11 |
Memory size |
The 200 group supports U disk data storage |
||||
12 |
Weight |
28 Kg |
Chongqing Gold Mechanical&Electrical Equipment Co.,Ltd was founded in 2008. We have a strong team including top sales, skilled engineers and we have our own manufacture with high quality. we mainly design and manufacture the Transformer Tester, Circuit Breaker Analyzer, CT PT Analyzer, Hipot Tester , Relay Tester and so on for more than 10 years.
After several years’ development, our products have become high intelligent and wide coverage. And our company has become one of the leading manufacturer of oil purifier and electrical testing equipment in China;
We have
developed sales channels in many countries such as UAE, Saudi
Arabia, Malaysia, Thailand, Pakistan, India, Germany,
Belgium, USA, Mexico, Kenya, Nigeria, South Africa and other
countries worldwide.
And we have
gained strong advantage and high reputation in international
market.
Certificates:
Exhibitions:
Click “Send” for more information!