Port | Shenzhen bay |
Packaging | Flight case. 83x68x102 cm. |
Lead Time | 5 |
M-900 plus | Yellow and white |
As a manufacturer, Siemantec has launched a new generation instrument—M-900 plus Automated Bioprocess Biochemistry Analyzer.
The accuracy and precision are proven to be reliable and the cost is low, fast speed, just 20s for a single item. All parameters are tested within 2min. Refer to the following link:
https://www.youtube.com/watch?v=OnuMoi-sBqg
M-900 plus uses immobilized enzyme membrane biosensor and ion selective electrode to detect the concentration of the sample to be measured.An oxidase corresponding to the test substrate is fixed in the enzyme membrane, and the substrate is catalyzed to produce hydrogen peroxide. The hydrogen peroxide is measured by a hydrogen peroxide electrode, and the concentration of the test substrate is calculated from the hydrogen peroxide concentration.
Ion-selective electrode(ISE) is a type of electrochemical sensor that can convert the changes in the activity of the ions in the solution into changes in the electrode potential, and the logarithm of the ion activity in the solution has a linear relationship with the electrode potential. “Ion-selective electrode” means that the sensor is only sensitive to specific ions. For example, the ammonium electrode is only sensitive to ammonium ions in the solution, but not sensitive to potassium and other ions.
M-900 plus automatically collects samples and imports them into the test area. The test substance contained in the sample generates an electrical signal on a specific electrode. The instrument calculates the concentration of the test object by collecting the electrical signals on the electrodes.Before the test, the instrument calibrates the standard with a known concentration.and the voltage value of the standard item is a measure of the concentration of the test substance. The unknown concentration can be obtained through the comparison with the voltage signal of the standard item. The sensor electrodes will be automatically cleaned by the system buffer solution after each measurement is completed, and the next test can be performed after cleaning.
Correlation between M-900 and HPLC results
Accuracy of Glucose concentration in cell medium |
|||
Number of samples | The average number test results mg/dl | SD | % CV |
50 | 68 | 1.36 | 2 |
50 | 189.6 | 3.41 | 1.8 |
50 | 265.7 | 5.05 | 1.9 |
50 | 351.2 | 5.27 | 1.5 |
50 | 501.8 | 10.04 | 2 |
50 | 619.6 | 12.39 | 2 |
Test principle | Enzyme electrode method |
Electrode | Single replaceable electrode |
Measuring range |
Glucose(Article number: C1001): 0.3~9 g/L
Glucose(Article number: G1001): 0.05~1 g/L Glutamine: 0.03~1 g/L Glycerin: 0.03~1 g/L Xylose: 0.03~1 g/L Lactate: 0.03~2 g/L Glutamate: 0.03~1 g/L Lysine: 0.03~1 g/L Methanol: 0.03~0.5 g/L Ethanol: .0.03~1 g/L The machine with pre-dilution function can expand the above test range by 10 to 30 times. NH4+: 2~30mmol/L, Na+: 60~200mmol/L, K+: 0.5~15mmol/L, Ca2+: 0.1~5mmol/L, pH: 6~8 |
Resolution | 0.01g/L; 0.01mmol/L |
Precision (CV%) | <2% |
Enzyme membrane life |
Glucose: ≤30 days, Lactate:≤30days, Glutamate: ≤30
days,
Lysine: ≤30 days, Ethanol / methanol: ≤10 days, Glutamine: ≤15days, Glycerin: ≤15 days, Xylose: ≤15 days, NH4+ electrode: ≥4 months, Na+ electrode: ≥6 months, K+ electrode: ≥6 months, Ca2+ electrode: ≥6 months, pH electrode: ≥4 months |
Ambient temperature | 10~35°C |
Relative humidity | ≤85% (no condensation water) |
External dimension | 660×530×520 mm |
Power supply | 110V or 220V, 50Hz, 60Hz, separate three-hole socket with good grounding |
Power | <100VA |
Weight | 35kg |
Screen | 10-inch color touch screen |
*Automatic injection and detection, automatic dilution is optional