Product Details
Product Description
1.Product
Introduce
The Fuji
FCX -AIII differential pressure (flow) transmitter accurately
measures differential pressure and converts it into an output
signal of 4~20mA DC.
Fuji
transmitter utilizes a unique micromachined capacitance silicon
sensor with advanced floating capsule structure and newer
micro-processing technology, the transmitter has high accuracy,
good stability, safety and reliability, and easy to use.
It's small
volume, light weight, good environment adaptability, and
applicable to all fields.
If using
the hand held communicator(sold separately), it can be set and
display via remote operation, without affecting the DC 4~20mA
output signal of transmitter.
Fuji FCX-AIII series transmitters with safety funtion have
obtained the certificate of SIL certification by TÜV.
2:Fuji FKC Transmitter Features
a.
High accuracy
Differential pressure
(flow) transmitter can be carried out with high accuracy
measurement in the range of 0.1~20000kPa.
Standard
accuracy: ± 0.065%
High
accuracy(optional):± 0.05%
There's
no need to linear calibration when carrying out zero
elevation
or suppression.
b.
Excellent environmental adaptaboility
The
advanced floating cell protects sensor from
temperature,static pressure and
overpressure effect, and controls the total measurement
error of the filed to the minimun.
c.
Excellent operability and easy to use
It has an
excellent operability and easy to use in any
application.
· All
range meet the requirements of explosion-proof.
· 5-digit
digital indiactor
·
Stainless steel AMP case
·Built-in
RFI filter and lightning arrester
· Various
anti-corrosive materials
·
Built-in local configurator with 3 push buttons
d.The transmitter can communicate using FUJI, HART,
communication
protocol, and also can use FOUNDATION FIELDBUS or PROFIBUS
protocol after changing the electronic
circuit.
3:Measured fluid: Liquid,Gas,or vapour
Range, operating pressure, and overrange
limit:
Output signal: (1)FKC: DC4~20mA+HART protocol
(2)FDC: FOUNDA TION Fieldbus protocol or
PROFIBUS-PA
Power
Supply:
General
|
DC10.5 ~
45V
|
Intrinsic
safety
|
DC10.5 ~
26V
|
With
arrestor
|
DC10.5 ~
32V
|
Ordering information
1. Model code
2. Span
3. Please select the direction of output (Notuse/OVER/UNDER) when
the transmitter is fault (Burnout). If unspecified, it is
Notuse.
4. Please select the output mode (linear or square root). If
unspecified, it is linear mode.
5. If the scale of indicator is selected to actual scale (9th
code:D,H,P,S), please select the items of display (digit,
scale,unit , etc).
6. Please select the tag plate according to need.(up to 14digit,
consist of lettters and numbers).
Xi'an
Tosi Da Technology Co., Ltd
Address:
RM11710,building3,ZhuQue,Street,YanTa,District,Xi'An
City,China.
www.fujitransmitter.com