1. Main Technical Parameters
2. Technical Index:
* Voltage control accuracy: ≤±0.5%F.S (F.S=360V)
* Current control accuracy: ≤±0.3%F.S (F.S=10A)
* Time control accuracy: ≤±10S/24H
* Voltage control range: 10%~100%F.S (F.S=360V)
* Current control range: 1%~100% F.S (F.S=10A)
* Charge current: 0~10A, or as per the user's requirement
* Discharge current: 0~10A, or as per the user's requirement
* Discharge capacity recovery efficiency: ≥95%
* Equipment charge efficiency: ≥95%
* Direct current output ripple: ≤5% DC (battery loaded 100%
current)
* Power factor: ≥95% (more than 50% load)
* Output harmonic content: <5%
* Power factor compensation: built-in, without reactive power
compensation
* Harmonic treatment: built-in, without any treatment
* Electricity supply transformer utilization: ≥90%
* Electricity saving benefit: 5%~8% (compared with silicon
controlled)
* Equipment dimension: 1200*800*2200 (mm)
3. Function:
* Set up formation process program and parameter
for all kinds of batteries; The program process can be set with
30 steps. The preset processes can be stored in the computer, and
can be recalled to any designated charger and discharger. The
processes can be uploaded to the computer via the monitor
software.
* With the working mode of constant current
charge, constant voltage charge, constant voltage
current-limiting charge, constant current voltage-limiting
discharge, circulation and standby;
* With the function of stage switch mode for
fixed time, fixed voltage, fixed current; and function of
recording running data at a fixed time;
* With the function of data storage during
over-current.