3.Function
Description of System Software
* Terminal
server(master station) data import function;
The data recorded by the terminal server(master station)
without software can be imported into the software and
processed.
* Data Curve Display Function
* Data processing function
Visual data processing, through the data curve can quickly
select the best test data.The selected data is
automatically calculated and processed and saved as an
internal data record.
* Support multiple protocols;
The software supports the data processing of the
JJF1101-2019 Environmental Test Equipment Temperature and
Humidity Calibration Specification and the JJF1564-2016
Temperature and Humidity Standard Box Calibration
Specification.
* Real-time data transmission function
The software can establish a connection with the terminal
server to realize real-time data upload and
processing.
* Historical Data Save, Manage, View
The software automatically saves the data imported from the
terminal server(master station) and the data uploaded in
real time,saves the data processing result, and can open
the view again, supports the name retrieval.
* Information management function
Software support sensor, sample, client, testing party and
other information management, for the software does not
have information can be automatically added. All
information can be exported to the Excel file.
* Real-time display function
When online with the terminal server(master station) , the
software displays the real-time data of each
channel.
* Real-time calculation of fluctuation and
uniformity
When online with the terminal server(master station) , the
software calculates the fluctuation and uniformity of the
temperature field in real time.
* Marking function of highest point and lowest
point
When online with the terminal server(master station), the
software automatically marks the highest and lowest
channels.
* Data viewing function
In data processing, you can view the data.
* Data correction function
The software supports temporary data correction.
* Low Power Indicator Function
When the power of the data recording terminal is
insufficient, the software prompts that the data recording
terminal should be charged.
* Multiple samples tested simultaneously
The terminal server(master station)can simultaneously
online 80 data recording terminals, put the data recording
terminals in different temperature fields, and realize the
simultaneous testing of multiple samples by creating
multiple test items on the software.