Port | Shanghai |
Packaging | Wooden package |
Lead Time | 7 working days after recepit of payment |
Application Scenarios
Household hybrid inverter, energy and efficiency saving,household emergency standby power supply, power supply for border posts, lighting in non power areas, communication base stations, nomadic areas, farms, small island villas, etc.
Product Features
Flexible and Grace
Battery reverse polarity protection
Technical
Specifications
Model | LEl-6K-SL | LEl-8K-SL | LEl-10K-SL | LEl-12K-SL |
PV Input | ||||
PV Input Power [W] | 7800 | 10400 | 13000 | 15600 |
Start-up Voltage [V] | 120 | |||
Max. PV Input Voltage [V] | 500 | |||
MPPT Voltage Range [V] | 125~500 | |||
MPPT Working Voltage For Full Load [V] | 264~460 | 352~460 | 220~460 | 264~460 |
MPPT Number/Max. Number Of Strings Per Channel | 4/2 | |||
Max. MPPT Input Current [A] | 24(12/12) | |||
Battery | ||||
Battery Type | Lithium,Lead-acid | |||
Number Of Battery Input | 2 | |||
Battery Voltage Range [V] | 85~460 | |||
Battery Voltage Range For Full Load [V] | 100~ 460 | 150~460 | 200~ 460 | 250~ 460 |
Max. Charge/Discharge Current [A] | 80/80 | |||
Communication | CAN/RS485 | |||
Charging Strategy For Battery | According to BMS Instructions/Stages (Lead-acid) | |||
AC Output (Grid-side) | ||||
Rated Output Power [W] | 6000 | 8000 | 10000 | 12000 |
Max. Output Current [VA] | 6600 | 8800 | 11000 | 13200 |
Rated Output Voltage [V] | ±120/240 | |||
Grid Voltage Range [V] | 211~264 | |||
Max. Output Current [A] | 25 | 30.3 | 41.6 | 50 |
AC Output Frequency [Hz] | 50/60 (45~54.9/54.9~65) | |||
Power Factor | 1 (0.8 leading~0.8 lagging) | |||
THDi (Rated Power) | <3% | |||
Backup AC Output (EPS) | ||||
Rated Backup Output Power [VA] | 6000 | 8000 | 10000 | 12000 |
Max. Backup Output Power [VA] | 7500 60s,9000 1s | 10000 60s,12000 1s | 12500 60s,15000 1s | 15000 60s,18000 1s |
Max. Output Current [A] | 31.2 | 41.6 | 52 | 62.5 |
Backup Output Voltage [V] | 110~120/220~240 Split Phase | |||
AC Frequency [Hz] | 50/60 (±0.2%) | |||
THDu (@linear load) | <3% | |||
Switch Time | <10ms | |||
Efficiency | ||||
Max. Efficiency | 98.2% | |||
General Data | ||||
Temperature Range [℃] | -25~+60 | |||
Relative Humidity | 0~95% | |||
Altitude [m] | 0~4000 (>2000 derating) | |||
Cooling Method | Smart fan cooling | |||
Noise [dB] | <40 | |||
Display | LCD | |||
Communication | RS485 (Standard);Wi-Fi/GPRS/Ethernet (Option) | |||
BMS Communication | RS485/CAN | |||
Weight [kg] | 32 | |||
Dimension (W*D*H) [mm] | 660*200*530 | |||
Installation Style | Wall-mounted | |||
Ingress Protection | IP65 | |||
Standby Self Consumption [W] | <10 | |||
Grid Standard | VDE4105/EN50549 | |||
Safety Standard | CE/IEC62109 | |||
Protection | ||||
DC Lightning Protection | Yes | |||
AC Lightning Protection | Yes | |||
PV Reverse Polarity Protection | Yes | |||
Battery Reverse Protection | Yes | |||
Insulation Resistor Detection | Yes | |||
Leakage Current Detection | Yes | |||
Anti-island Protection | Yes | |||
Grounding Fault | Yes | |||
Input Overvoltage & Undervoltage | Yes | |||
Output Overvoltage & Undervoltage | Yes | |||
Input Over Current | Yes | |||
Output Over Current | Yes | |||
Overheat Protection | Yes |
Application Principle