MOQ | 1 EA |
Port | BUSAN, INCHEON |
Brand | SDT | Model | SDT-420 |
Size(Capacity) | 300 mm ~ 5000 mm | Weight | Level measurement |
Material | Carbon Steel, 316SS, Aluminum | Color | Depends on size, specification |
Dimensions | Depends on size, specification | Features | accuracy ±0.5% of Rate (Option : ±0.2 %), Repeatability/Reproducibility 0.05% / ±0.2 |
System Design | Measurement Principle | Buoyancy-continuous displacement utilizing a precision torsion bar |
Measurement Medium | Liquid (Max. Viscosity : 1500 cP) | |
Input | Measurement Variable | Level, Determined by load cell affected by buoyancy force changes on continuous displacer |
Measuring Range | Up to 5,000mm based on displacer length (Consult factory for longer ranges) | |
Output | Type | 4 to 20mA with HART communication 3.75 to 22.5mA useable |
LCD Window Display | Bar graph, mm, inch, %, mA | |
Resolution | Analog : 0.01mA | |
Loop Resistance | 240Ω @24V DC | |
Diagnostic Alarm | 3.3, 22mA or HOLD selectable | |
Damping | Adjustable 1-30 seconds | |
Sampling Rate | Transmitter 10 times per second | |
User Interface | Keypad | 4-button menu-driven data entry and system security |
Indication | Bar graph, HART Communication, 2 line x 4-charator LCD display | |
Power | Measured at Instrument Terminals |
15-30V DC HART This device is operated under only functional isolation |
Current |
Minimum 3.75mA, Maximum 22.5mA This device provides only functional isolation |
|
Housing | Material | Aluminum alloy ADC12 (KS;ALDC8, ASTM;383), 316LSS |
Cable Entry | 1/2”PF(std.) | |
Ingress Protection | IP67 (NEMA 4) | |
Chamber | Materials | Carbon steel, 304/316/316L Stainless Steel |
Wetted Parts | 316/316L and Inconel, Hastelloy-C (Torque Tube) | |
Process Connections |
Tank Top : 3”, 4” ANSI Flange
Chambered : 1”, 1-1.2”, 2”S/W, Flange
|
|
Process Condition | Process Temperature Range | -20 to 450℃ |
Process Pressure Range | 200kgf/㎠@25℃ | |
Environment | Electrics Operating Temp | -20 to 80℃ |
Humidity | 0-99%, Non-condensing | |
Electromagnetic Compatibility | CE Requirement EN61000-6-2-2005, EN61000-6-4-2007 | |
Natural Frequency | 42.7 (X axis), 109.6(Y axis), 127.4(Z axis) | |
Level Performance | Linearity | ± 0.5% of full span |
Accuracy | ± 0.5% of full span (Option : ± 0.25% of F.S) | |
Repeatability | ± 0.05% of full span | |
Hysteresis | ± 0.05% of full span | |
Warm-up Time | < 3 seconds | |
Certificate | ATEX, KC, CE, KOSHA, KTL, KEPIC | |
Warranty Period | 1year |