size | 96*96 |
Introduction
Product Features
Automatic calibration function, easy to operate, simple and
quick;
With panel error correction features to ensure more
accurate;
Bilayer, two tone four digital display;
The perfect combination of triple anti-interference technology to
ensure system stability;
Using a variety of alarm mode, power protection, safe and
reliable;
Complete specifications, compatible with a variety of pressure
input signal;
More than 20,000 hours trouble-free operation;
Providing single or dual linear output;
Available in a variety of voltage (for example, 0 ~ 10V) or
current (for example, 4 ~ 20mA) linear output signal;
Providing RS485 computer communication interface
;
Providing the same pressure point / temperature dual
measurement and dual display. Supporting E, J, K, S-type
thermocouple and Pt100 other RTD input. (For PS1016T
only)
Specifications
1. Digital display: four digital display with two layers and
double colours;
2. Internal Resolution: 32000;
3. External Resolution: 0.01Mpa, 0.02Mpa, 0.05Mpa panel switch (outage protection setting is more than 40 years);
4. Nonlinear: 0.05% 1, 0.1% 1, 0.2% 1, 0.5% 1;
5. Two-way alarm setting Upper limit is 0~99.99MPa Lower limit is 0~99.99MPa;
6. Relay ratings: 250VAC•A5A;
7. Environment temperature: -10~+ 50 ;
8. Environment humidity: 80% or less RH;
9. Power supply: 85~265V AC;
10. Continuous trouble-free working time is more than 50000 hours.
Order Format
Format
: PS1016- range code - power code - output code - alarm code -
input code - shape code - Temperature Code - Communication
Code
Example 1: PS1016-035-200-311
Product Model "PS1016", intelligent digital pressure
indicator.
Pressure range code " 035 " , which means that the pressure range
is 0 ~ 35MPa;
The output signal code " 200" indicates no linear signal output
;
Alarm code " 311" , adopts two-way relay top and bottom
limitation alarm;
Vacancies and not marked function codes are the default
values.
Example 2: PS1016-050-122-205-311-433-5D-7R
Product Model "PS1016", intelligent digital pressure
indicator.
Pressure range code " 050" , which means that the pressure range
is 0 ~ 50MPa;
Power code " 122 " , which means the power supply is 220VAC
;
Output signal code " 205 " , adopts 4 ~ 20mA linear signal
output;
Alarm output code " 311" , adopts two-way relay top and bottom
limitation alarm ;
Input signal code " 433 " , mating for the transducer that has
3.33mV / V output ;
Dimensions Coding "5D", the overall dimension is 96 *
96mm;
Temperature measurement code vacancies , which means that
no temperature measurement function ;
Communication Code "7R", adopts RS485 communication
interface.