QT-1010 automatic microclimate measurement system is used for automatic monitoring of ten weather elements such as wind direction, wind speed, rainfall, air temperature, relative humidity, air pressure, solar radiation, photosynthetically active radiation, soil temperature, and soil humidity. Other measurement elements can be customized according to user needs, such as evaporation, hours of sunlight, photosynthetically active radiation, soil heat flux, net radiation, etc. The measurement height is generally 2-6 meters, which varies according to the height difference of vegetation. The farmland microclimate station provides good support for agricultural scientific research, agricultural production, and animal husbandry.
The formation of ecological microclimate is based on the local topography and macroclimate. At the same time, the characteristics of microclimate change with the type, variety, growth period and growth status of crops, resulting from the interaction of the atmosphere, soil and crops. In long-term ecosystem monitoring, monitoring of meteorological factors is necessary. Air temperature, precipitation, humidity, sunshine, wind direction, and wind speed are important ecological factors, as well as important factors affecting plant growth and development. These factors not only have characteristics of daily change, monthly change, seasonal change, but also annual changes. It is of great significance to carry out long-term monitoring of these meteorological factors, summarize their changing laws, and seek their relationship with plant growth.
QT-1010 Automatic Microclimate Measurement System
System Features:
l Complete agricultural meteorological system, suitable for agricultural production, scientific research and standard measurement
l Easy to install and maintain
l High measurement accuracy, no manual intervention required
l Flexible composition of elements
l Data collection density can be set by yourself
l Status monitoring
l Support AC / solar power supply
l Maintenance-free, suitable for field applications
l Can be used in single-site applications or network locations, wireless data transmission
l Large-capacity data storage
Network management software (optional):
QT-1010 Automatic Microclimate Measurement System
a) Management function: It has functions of hierarchical management of data and management of monitoring points.
b) Collection function: collect the soil moisture monitoring data at the monitoring point.
c) Alarm function: data alarm function.
d) Query function: The monitoring system software can query various historical records.
e) Storage function: The front-end monitoring equipment has a large capacity data storage function; the monitoring center database can record all historical data.
f) Analysis function: The data can generate curves and reports for trend analysis.
Acquisition system technical parameters:
CR1000
Data collector
Technical Parameters
Maximum sampling frequency
100Hz
Analog channel
8 differential channels (16 single-ended channels)
Pulse channel
2
Control output
8
Excitation channel
3 voltage channels
Other ports
4 SDI-12 or 4 RS232 (shared with 8 control output interfaces)
Data communication port
1 CS I / O; 1 RS-232; 1 parallel peripheral
Signal input range
± 5000mV
A / D conversion accuracy
13-bit analog / digital conversion
Measurement resolution
0.33 µV
measurement accuracy
± (reading * 0.06% + offset), 0 ~ 40 ℃
Built-in storage space
4M
Supply voltage
9.6 ~ 16VDC
Power consumption
Sleep mode: 0.6mA, 1Hz acquisition frequency: 4.2mA
size
23.9 × 10.2 × 6.1cm
Operating temperature
-25 ~ 50 ℃; -55 ~ 85 ℃ (extended)
Meteorological sensor technical parameters:
200-03002 wind speed and direction sensor
200-03002
Technical Parameters
Wind speed measurement range
0-50 m / s
Wind direction measurement range
360 degree mechanical, 355 degree electronic.
Wind speed measurement accuracy
± 0.49 m / s
Wind direction measurement accuracy
± 5 degrees
Wind speed
1.1 m / s
Damping ratio
0.2
Wind speed signal output
Electromagnetically induced AC sinusoidal voltage, 1 pulse per loop.
Wind direction signal output
10K potentiometer, linearity: 0.5%
Potentiometer excitation
5-15VDC
Linear adapter
12-30VDC
Mounting rod diameter
34mm
Sensor net weight
0.7Kg
CS215 temperature and humidity sensor
CS215
Technical Parameters
Temperature Sensor
Measuring range
-40 ~ 70 ℃
measurement accuracy
± 0.3 ℃ (at 25 ℃), ± 0.4 ℃ (5 ~ 40 ℃), ± 0.9 ℃ (-40 ~ 70 ℃)
Response time
<120 s
Output resolution
0.1 ℃
Relative humidity sensor
Measuring range
0 ~ 100% RH (at -20 ~ 60 ℃)
measurement accuracy
(At 25 ℃): ± 2% (10 ~ 90% RH); ± 4% (0 ~ 100% RH)
Temperature dependence
Better than ± 2% (at 20 ~ 60 ℃)
Short-term lag
< 1.0% RH
Long-term stability
Better than ± 1% RH / year
Response time
<10 s (63%, wind speed 1m / s)
calibration
NIST, NPL
Other technical parameters
Supply voltage
6 ~ 16VDC (12VDC interface of data collector is recommended)
Current consumption
120μA at rest, 1.7mA at measurement (for 0.7 seconds)
Operating temperature
-40 ~ 70 ℃
size
18cm in length, 1.2cm / 1.8cm in diameter (probe end / cable end)
weight
150g
CS106 barometric pressure
CS106
Technical Parameters
model
CS106 / PTB110
Range
500 ~ 1100hPa
Total accuracy
± 0.3hPa @ 20 ℃
± 0.6hPa @ 0 ~ 40 ℃
± 1.0hPa @ -20 ~ 45 ℃
± 1.5hPa @ -40 ~ 60 ℃
Repeatability
± 0.03hPa
Long-term stability
± 0.1hPa / year
Resolution
± 0.01mb
Response time
500 ms
Operating temperature
-40 ~ 60 ℃
Energy consumption
Working state <4mA
Sleep state <1μA
powered by
10 ~ 30VDC
size
6.8cm × 9.7cm × 2.8cm
weight
90g
TE525MM rainfall
TE525MM
Technical Parameters
sensor type
Magnetic reed switch
Output
Switch signal
Accuracy
1.0% up to 2 "/ hr (50 mm / hr)
Collector size
24.5cm diameter x 29.21cm high
Collector area
214cm2
Operating temperature
0 ~ 50 ℃
cable length
12 meters
material
Anodized aluminum
SP-510 total radiation sensor
SP-510
Technical Parameters
model
SP-510 (up)
SP-610 (downward)
Sensitivity
0.057mV per W / m2
0.15mV per W / m2
Calibration factor
17.5W / m2 per mV
6.7W / m2 per mV
Calibration output range
0 ~ 114mV
0 ~ 300mV
visual field
180 °
150 °
Measuring range
0 ~ 2000 W / m-2
Spectral range
385nm ~ 2105nm
Repeatability
less than 1%
Long-term drift
Less than 2% / year
Non-linear
less than 1%
Response time
0.5 seconds
Heater
780Ω, 15.4 mA
185mW power at 12VDC
Operating temperature
-50 ~ 50 ℃; 0 ~ 100% relative humidity
size
Diameter: 23.5mm, height: 28.7mm
weight
90g
100g
SQ-500 photosynthetically active radiation
SQ-500
Technical Parameters
Sensor model
SQ-500
SQ-512
SQ-515
Output
0.01mV per μmol / m2 / s
0.6mV per μmol / m2 / s
0.8mV per μmol / m2 / s
Output range
0 ~ 40mV
0 ~ 2.5VDC
0 ~ 5VDC
power supply
Self-powered
5.5V ~ 24VDC 12V: 54μA
Measuring range
0 ~ 4000μmol / m2 / s
Spectral range
389 ~ 692nm
Repeatability
Less than 0.5%
stability
Less than 2% per year
Response time
1ms
Measurement perspective
180 °
cable length
5m shielded cable
size
2.4cm diameter, 3.5cm high
weight
100g (including 5m cable)
CS655 soil moisture temperature conductivity
CS655
Technical Parameters
Relative permittivity
range
1 ~ 81
Accuracy
(1 ~ 40): ± (3% of reading + 0.8) solution EC ≤8 dS / m)
(40 ~ 81): ± 2 solution EC ≤2.8 dS / m
accuracy
<0.02
Volume water content
range
5% ~ 50%
Accuracy
± 3% VWC (standard mineral soil), solution EC ≤10 dS / m
accuracy
<0.05%
Conductivity
Measuring range
0 ~ 8 dS / m
Accuracy
± (5% of reading + 0.05dS / m)
accuracy
0.5% of BEC
Soil temperature
range
-10 ° ~ + 70 ° C
Accuracy
± 0.5 ° C (buried in soil)
accuracy
± 0.02 ° C
Sensor parameters
Sensing volume
3600 cm3 (0 ~ 7.5 cm radius around the probe, 4.5 cm below the probe tip)
Electromagnetic
Meet CE standard, EN61326 requirements, anti-static discharge protection
Operating temperature
-10 ° ~ + 70 ° C
Probe size
Length: 120mm; diameter: 3.2 mm
Probe interval
32 mm (1.3 in.)
Probe size
85 mm (3.3 in.) * 63 mm (2.5 in.) * 18 mm (0.7 in.)
Sensor weight
240 g (without cables)
Sensor output
SDI-12; serial RS-232
Preheat time
3s
measure time
3 ms measurement, 600 ms complete execution command
power supply
6 ~ 18 VDC, must meet 45 mA @ 12 Vdc
Power loss
Dynamic (3 ms): 45 mA typical @ 12 Vdc
Sensor weight
280 g (9.9 oz.) (Without cables)
Origin: United States