Please wait while your account is being registered at Tradewheel.com Loading Spinner

Join World's Fastest Growing B2B Network

QT-1010 Automatic Microclimate Measurement System

Product Details

QT-1010 automatic microclimate measurement system is used for automatic monitoring of ten weather elements such as wind direction, wind speed, rainfall, air temperature, relative humidity, air pressure, solar radiation, photosynthetically active radiation, soil temperature, and soil humidity. Other measurement elements can be customized according to user needs, such as evaporation, hours of sunlight, photosynthetically active radiation, soil heat flux, net radiation, etc. The measurement height is generally 2-6 meters, which varies according to the height difference of vegetation. The farmland microclimate station provides good support for agricultural scientific research, agricultural production, and animal husbandry.

The formation of ecological microclimate is based on the local topography and macroclimate. At the same time, the characteristics of microclimate change with the type, variety, growth period and growth status of crops, resulting from the interaction of the atmosphere, soil and crops. In long-term ecosystem monitoring, monitoring of meteorological factors is necessary. Air temperature, precipitation, humidity, sunshine, wind direction, and wind speed are important ecological factors, as well as important factors affecting plant growth and development. These factors not only have characteristics of daily change, monthly change, seasonal change, but also annual changes. It is of great significance to carry out long-term monitoring of these meteorological factors, summarize their changing laws, and seek their relationship with plant growth.

QT-1010 Automatic Microclimate Measurement System

System Features:

l Complete agricultural meteorological system, suitable for agricultural production, scientific research and standard measurement

l Easy to install and maintain

l High measurement accuracy, no manual intervention required

l Flexible composition of elements

l Data collection density can be set by yourself

l Status monitoring

l Support AC / solar power supply

l Maintenance-free, suitable for field applications

l Can be used in single-site applications or network locations, wireless data transmission

l Large-capacity data storage

Network management software (optional):

QT-1010 Automatic Microclimate Measurement System

a) Management function: It has functions of hierarchical management of data and management of monitoring points.

b) Collection function: collect the soil moisture monitoring data at the monitoring point.

c) Alarm function: data alarm function.

d) Query function: The monitoring system software can query various historical records.

e) Storage function: The front-end monitoring equipment has a large capacity data storage function; the monitoring center database can record all historical data.

f) Analysis function: The data can generate curves and reports for trend analysis.

Acquisition system technical parameters:

CR1000

Data collector

Technical Parameters

Maximum sampling frequency

100Hz

Analog channel

8 differential channels (16 single-ended channels)

Pulse channel

2

Control output

8

Excitation channel

3 voltage channels

Other ports

4 SDI-12 or 4 RS232 (shared with 8 control output interfaces)

Data communication port

1 CS I / O; 1 RS-232; 1 parallel peripheral

Signal input range

± 5000mV

A / D conversion accuracy

13-bit analog / digital conversion

Measurement resolution

0.33 µV

measurement accuracy

± (reading * 0.06% + offset), 0 ~ 40 ℃

Built-in storage space

4M

Supply voltage

9.6 ~ 16VDC

Power consumption

Sleep mode: 0.6mA, 1Hz acquisition frequency: 4.2mA

size

23.9 × 10.2 × 6.1cm

Operating temperature

-25 ~ 50 ℃; -55 ~ 85 ℃ (extended)

Meteorological sensor technical parameters:

200-03002 wind speed and direction sensor

200-03002

Technical Parameters

Wind speed measurement range

0-50 m / s

Wind direction measurement range

360 degree mechanical, 355 degree electronic.

Wind speed measurement accuracy

± 0.49 m / s

Wind direction measurement accuracy

± 5 degrees

Wind speed

1.1 m / s

Damping ratio

0.2

Wind speed signal output

Electromagnetically induced AC sinusoidal voltage, 1 pulse per loop.

Wind direction signal output

10K potentiometer, linearity: 0.5%

Potentiometer excitation

5-15VDC

Linear adapter

12-30VDC

Mounting rod diameter

34mm

Sensor net weight

0.7Kg

CS215 temperature and humidity sensor

CS215

Technical Parameters

Temperature Sensor

Measuring range

-40 ~ 70 ℃

measurement accuracy

± 0.3 ℃ (at 25 ℃), ± 0.4 ℃ (5 ~ 40 ℃), ± 0.9 ℃ (-40 ~ 70 ℃)

Response time

<120 s

Output resolution

0.1 ℃

Relative humidity sensor

Measuring range

0 ~ 100% RH (at -20 ~ 60 ℃)

measurement accuracy

(At 25 ℃): ± 2% (10 ~ 90% RH); ± 4% (0 ~ 100% RH)

Temperature dependence

Better than ± 2% (at 20 ~ 60 ℃)

Short-term lag

< 1.0% RH

Long-term stability

Better than ± 1% RH / year

Response time

<10 s (63%, wind speed 1m / s)

calibration

NIST, NPL

Other technical parameters

Supply voltage

6 ~ 16VDC (12VDC interface of data collector is recommended)

Current consumption

120μA at rest, 1.7mA at measurement (for 0.7 seconds)

Operating temperature

-40 ~ 70 ℃

size

18cm in length, 1.2cm / 1.8cm in diameter (probe end / cable end)

weight

150g

CS106 barometric pressure

CS106

Technical Parameters

model

CS106 / PTB110

Range

500 ~ 1100hPa

Total accuracy

± 0.3hPa @ 20 ℃

± 0.6hPa @ 0 ~ 40 ℃

± 1.0hPa @ -20 ~ 45 ℃

± 1.5hPa @ -40 ~ 60 ℃

Repeatability

± 0.03hPa

Long-term stability

± 0.1hPa / year

Resolution

± 0.01mb

Response time

500 ms

Operating temperature

-40 ~ 60 ℃

Energy consumption

Working state <4mA

Sleep state <1μA

powered by

10 ~ 30VDC

size

6.8cm × 9.7cm × 2.8cm

weight

90g

TE525MM rainfall

TE525MM

Technical Parameters

sensor type

Magnetic reed switch

Output

Switch signal

Accuracy

1.0% up to 2 "/ hr (50 mm / hr)

Collector size

24.5cm diameter x 29.21cm high

Collector area

214cm2

Operating temperature

0 ~ 50 ℃

cable length

12 meters

material

Anodized aluminum

SP-510 total radiation sensor

SP-510

Technical Parameters

model

SP-510 (up)

SP-610 (downward)

Sensitivity

0.057mV per W / m2

0.15mV per W / m2

Calibration factor

17.5W / m2 per mV

6.7W / m2 per mV

Calibration output range

0 ~ 114mV

0 ~ 300mV

visual field

180 °

150 °

Measuring range

0 ~ 2000 W / m-2

Spectral range

385nm ~ 2105nm

Repeatability

less than 1%

Long-term drift

Less than 2% / year

Non-linear

less than 1%

Response time

0.5 seconds

Heater

780Ω, 15.4 mA

185mW power at 12VDC

Operating temperature

-50 ~ 50 ℃; 0 ~ 100% relative humidity

size

Diameter: 23.5mm, height: 28.7mm

weight

90g

100g

SQ-500 photosynthetically active radiation

SQ-500

Technical Parameters

Sensor model

SQ-500

SQ-512

SQ-515

Output

0.01mV per μmol / m2 / s

0.6mV per μmol / m2 / s

0.8mV per μmol / m2 / s

Output range

0 ~ 40mV

0 ~ 2.5VDC

0 ~ 5VDC

power supply

Self-powered

5.5V ~ 24VDC 12V: 54μA

Measuring range

0 ~ 4000μmol / m2 / s

Spectral range

389 ~ 692nm

Repeatability

Less than 0.5%

stability

Less than 2% per year

Response time

1ms

Measurement perspective

180 °

cable length

5m shielded cable

size

2.4cm diameter, 3.5cm high

weight

100g (including 5m cable)

CS655 soil moisture temperature conductivity

CS655

Technical Parameters

Relative permittivity

range

1 ~ 81

Accuracy

(1 ~ 40): ± (3% of reading + 0.8) solution EC ≤8 dS / m)

(40 ~ 81): ± 2 solution EC ≤2.8 dS / m

accuracy

<0.02

Volume water content

range

5% ~ 50%

Accuracy

± 3% VWC (standard mineral soil), solution EC ≤10 dS / m

accuracy

<0.05%

Conductivity

Measuring range

0 ~ 8 dS / m

Accuracy

± (5% of reading + 0.05dS / m)

accuracy

0.5% of BEC

Soil temperature

range

-10 ° ~ + 70 ° C

Accuracy

± 0.5 ° C (buried in soil)

accuracy

± 0.02 ° C

Sensor parameters

Sensing volume

3600 cm3 (0 ~ 7.5 cm radius around the probe, 4.5 cm below the probe tip)

Electromagnetic

Meet CE standard, EN61326 requirements, anti-static discharge protection

Operating temperature

-10 ° ~ + 70 ° C

Probe size

Length: 120mm; diameter: 3.2 mm

Probe interval

32 mm (1.3 in.)

Probe size

85 mm (3.3 in.) * 63 mm (2.5 in.) * 18 mm (0.7 in.)

Sensor weight

240 g (without cables)

Sensor output

SDI-12; serial RS-232

Preheat time

3s

measure time

3 ms measurement, 600 ms complete execution command

power supply

6 ~ 18 VDC, must meet 45 mA @ 12 Vdc

Power loss

Dynamic (3 ms): 45 mA typical @ 12 Vdc

Sensor weight

280 g (9.9 oz.) (Without cables)

Origin: United States