Quantity | 1 - 5 |
Price | USD295.00 |
Port | shenzhen port |
Packaging | 20X22X15CM |
Lead Time | 3-5 working days after payment |
Animal use infusion pump
Model:MS-P30Vet
Main features:
1.3.5” colorful touch screen, easy to operate with human-computer interface.
2.Unique doorless design, visible place the IV set directly, convenient and quick. Dual CPU control.
3.IP34 dustproof and waterproof design. AC/DC power, Larger battery, long working time.
4.Reduce the bubbles error alarm because horizontal place the IV set design.
5.Very Light weight only 1.3 KG, small and exquisite, convenient to carry and transport.
6.DPS dynamic pressure monitoring, real-time display of the current pressure value.
7.Use German high-end medical grade motor driver chip! The unique patented silent technology reduces noise to 12dB, keeping stable operation at high and low speed, anti-shake, Power Saving, Micro-stepping and more accurate infusion, Reduces resonance, Saves energy and reduces consumption, and Efficiently cools down to keep the motor at a constant temperature.
8. New independent 3 stage peristaltic device design with exclusive patented technology and First one in the global market, which it making infusion set stress evenly and improving infusion accuracy and extending the life of infusion pump and IV set, reduce workload and make the patient more comfortable in infusion process.
Specification:
3.5”touch screen
Size: L165 × W103 × H100mm. Weight: 1.3kg.
Power: 100~240V, External DC Power: 12V~15V
Battery: 2600mAh, working 10 hours in 25ml/h speed.
Double CPU. IP34warterproof / dustproof/shockproof.
Flow Rate range: 0.1~2000.00ml/h, increment 0.01ml/h.
VTBI: 0.1-9999.99ml, Time: 1s-99h59min.
KVO: 0.1~5.0ml/h, increment 0.1ml/h.
Accuracy: ±5% (use the IV set calibrated)
Purge: 0.1-2000ml/h. IV sets: Dia3-5mm or setting
Bolus rate: 0.1~2000ml/h, Automatic/Manual bolus available
Anti-bolus: Automatically reduce the tube pressure when the tube is blocked.
Bubble size: Adjustable 50/100/250/500/800μl. Ultrasonic detection.
Occlusion pressure : Adjustable Low /Medium /High.Double Pressure detection
History Record: 2000 above. Night mode: setting and adjustable.
Temperature:-20℃-55℃,Relative humidity:10%-95%,
Atmospheric pressure: 40~120Kpa.
Alarm: Air in Line / Downstream Occlusion / UPstream Occlusion / No Battery / VTBI Completed / KVO Finished / System Error / No Infusion Tube / Standby Time Expired / Reminder / Low Battery /No Battery inserted / Time Near End / No AC Power.
Infusion Mode : Rate Mode/Time Mode/Weight Mode/Sequential Mode.
IV Set: 2 built-in brand for choice, and can User defined: Common IV set / Specified IV set / Light-proof IV set / Precision IV set.
Room319-509,Block B,Headquarter Economic Building,Xixiang Road,Baoan District,Shenzhen,Province of China