Product Details

PC-66A pulse oxygen saturation meter

First, performance characteristics

1. 3.5 inches high rate LCD color screen display parameters and waveforms

2. Can show pulse oxygen saturation, pulse rate, blood flow perfusion index, body temperature, blood oxygen volume waveform, pulse strength column chart

3. 500 hours of monitoring data and trend data storage

4. Through Bluetooth to upload data to the mobile phone

5. Equipped with rechargeable 2000mAh lithium battery ultra-long battery life, full power can be used for 18 hours

6. Bring your own metal bracket and base, gravity sensing for horizontal / vertical screen display direction switching, configuration lock screen mode, easy to read values

7. Can be external adult finger clip probe, ear temperature probe, newborn blood oxygen probe

8. Full Chinese menu, can set the alarm upper and lower limit / time / volume / automatic shutdown and many other functions, implanted in the newborn bundle tutorial

9. Data can be uploaded to the PC side for analysis

Features:

Second, technical parameters

Oxygen saturation (SpO2)

Measurement range: 35% to 100%

Measurement accuracy: 75% to 100%: ±2%

50%~75%:±3%

Alarm range: ≤ 95%

Exceeding tip setting range: 50%-99%

Pulse Rate (PR)

Measurement range: 30bpm to 250bpm

Accuracy: ± 2% or ± 2bpm for a large value

Exceeding tip setting range: Upper limit: 100bpm-240bpm

Lower limit: 30bpm-99bpm

Blood Flow Perfusion Index (PI)

Display range: 0.2% to 20%

Body temperature (TEMP)

Display range: (32.0 to 43.0)

Measurement error: in the (35.0 to 42.0) range of ±0.2 degree±s C;

Measurement time: less than 5 seconds

Measured population: adults, infants and young children

Measurement site: Ear cavity

Clinical bias: ≤ 0.1 degrees C

Anti-jamming

Resistance to natural light interference: When used in natural light environments, pulse oxygen saturation and pulse rate measurements meet the above criteria.

Anti-artificial light interference capability: Pulse oxygen saturation and pulse rate measurements meet the above criteria when the light environment is a light frequency light source.

Specifications:

Host form factor: 158mm long, 73mm wide, 25mm thick

Net weight: about 230g (battery included)

Storage:

Ambient temperature: -20 degrees C to 45 degrees C

Relative humidity: 10 to 95%

Atmospheric pressure range: 50kPa to 107.4kPa