MOQ | 1 Piece/Pieces |
Place of Origin | Germany | Brand Name | Optibelt |
Model Number | Opti-TT | Electricity consumption | max. 12 mA |
Measurement range | ACC:1-16 Hz EMW: 6- 600Hz | Scope of supply | Rate monitor + battery + bag |
Weight | 480 g |
https://www.optibelt.com/en/products/technical-devices/optibelt-tt/
1. How do I turn on the Tester?
Push the red button on top of the tester 1 second.
The display illuminates.
2. Why does the tester not turn on? Do I have to
charge the battery first?
The tester requires the measuring head to be attached
to turn on. A new tester will come with a full charge
and show a full green area on the battery symbol on
the display. As a spacing aid for large or small
distances, do not use the red points of light but use
the target crosses and/or the "belt" symbols at the
sides instead.
3. The frequency mode and range is shown in a
frame on the top of the display. How do I change
from "EM: 6–600Hz" to "AC: 1–16Hz"?
The frequency mode and range is automatically
calibrated when the measuring head is changed.
4. Why does the display turns black after 30
seconds and the last shown measuring result?
The device enters STAND BY mode to save energy. To
turn on the display simply move the device. After 5
minutes of no movement, the device changes to AUTO
OFF.
Note: If the red button is pressed all prior
measurements will be cleared.
Note: Switch off the device while using rolling tool
boxes. Press the red button 2 seconds.
5. Does the tester use the red lights for
measurement in EM mode?
No, the tester uses invisible electromagnetic (EM)
waves for measurement.
6. What are the red lights used for in EM
mode?
The red lights are used as a visual guide to position
the tester properly over the belt. The two dots
should be touching when the distance between the
measuring head to the belt is 40–65 mm.
7. Why do the red lights turn off
sometimes?
The red lights will turn off when too much movement
is detected.
The display shows "Rapid move".
Hold the tester still and the display will show
"Ready".
8. The space over the belt is only 30mm. Is this
enough for measurement?
Yes. The minimum distance for an accurate reading is
10 mm. (The height of the measuring head is 20
mm.)
Note: It is only necessary to charge the battery when
the red battery symbol is flashing or the battery is
empty and the screen is black.
9. Why do the measurements sometimes show a large
variation in EM mode? The position of the measuring
head is good.
Your finger may be interferring with the measurement.
Pluck the belt with your finger to the side of the
measuring head.
Note: For longer belts, smaller "plucking" is needed
for an accurate reading.
10. How do you charge the battery? Can the battery
be replaced?
Use the included USB charger and wall socket
attachment.
Note: When fully charged the red status indicator
will turn off after 3 hours.
Yes the battery can be replaced.
Note: The battery can be charged over 1000 times.
11. How many measurements can I take on a fully
charged battery?
The tester can take over 300 measurements before the
battery needs to be recharged