GDB-D multi-function Z type transformer turns ratio ttr
meter
GDB-D Z Type Three Phase Transformer Turns Ratio Meter Is
Specially Designed For Three-Phase Transformer In Power
System, Especially For Transformer Of Type Z Winding And
Other Transformers Whose Zero-Load Current Is Relatively
High.
Feature:
-
The tester has a wide test range, fast test speed and
good repeatability.
-
Flexible data processing, convenient connection and
perfect protection.
-
Easy to learn and use
-
Suitable for Z-connected transformers.
-
Two output voltages are optional, suitable for
transformers with high zero load current.
-
The test range is wide, and the highest conversion rate
can reach 10,000.
-
Automatic calculation of tap position.
-
Fast speed, three phases only 18 seconds.
-
Good repeatability.
-
Automatically save up to 99 data.
-
Flexible data processing, including retrieval, printing,
transmission to a USB flash drive, deletion and upload to
a PC for testing.
-
Transformer short-circuit protection and turn-to-turn
short circuit.
-
Protection function, if short circuit occurs, relevant
information will be displayed on the LCD screen.
-
Light weight and small size.
Attentions
-
For transformer with 19-step load tap switch, steps 9, 10
and 11 are tapped to the same value. The tester shall put
in 17 for tap type. At this time, after step 12 is
tapped, the tap position displayed on the tester is 2
smaller than the actual position.
-
When error information is displayed, the power shall be
turned off before clearing the error.
-
Wires shall be connected well. The tester shall be
earthed well!
-
When the tester is in service, if the display on LCD
screen is unreadable and there is no response after
pressing "↑" and "↓", or the measured value is far
different from the actual value, please press the Reset
key or turn off the power, and then repeat your
operation.
-
If there is no character displayed on the screen or the
color of character is very light, please turn the
luminance potentiometer to an appropriate position.
Luminance potentiometer is a multiturn potentiometer with
10 turns!
-
Working place of the tester shall be far from strong
electric field, strong magnetic field and high-frequency
equipment. The smaller disturbance of electric power
supply is, the better it will be, and electric power
supply should use illuminating line. If distance of
electric power supply is still relatively intense, AC
clean power supply may be used to provide power supply to
the tester, as long as the capacity of AC clean power
supply is greater than 200VA.
-
The tester shall be stored at a dry place with favorable
ventilation. If it is stored for a long period or in a
damp environment, the warm up time shall be prolonged to
remove moisture before use.
Specifications
Item Name
|
Z Type Reliable
Three Phase ttr testing set
|
Transformation ratio testing range
|
0.8-10000
|
Group testing range
|
1-12
|
Ransformation ratio testing accuracy
|
0.2 (180V: 0.8~1000) 0.5 (180V:
1000~10000)
0.2%(
0.8~200)
|
Turns ratio resolution
|
0.0001
|
Power input
|
220V±10% 50HZ±1Hz
|
Service temperature
|
-20℃~40℃
|
Relative humidity
|
≤85% no condensation
|
Dimension
|
48*40*29CM
|
Weight
|
14Kg
|