LC1D65ABD TeSys D contactor – 3P(3 NO) – AC-3 –

Product Details

range product name product or component type device short name contactor application utilisation category poles description power pole contact composition [Ue] rated operational voltage [Ie] rated operational current motor power kW motor power HP (UL / CSA) control circuit type [Uc] control circuit voltage auxiliary contact composition [Uimp] rated impulse withstand voltage overvoltage category [Ith] conventional free air thermal current Irms rated making capacity rated breaking capacity [Icw] rated short-time withstand current associated fuse rating average impedance [Ui] rated insulation voltage electrical durability power dissipation per pole Front cover mounting support standards product certifications connections – terminals tightening torque operating time safety reliability level mechanical durability maximum operating rate
TeSys
TeSys D
Contactor
LC1D
Motor control
Resistive load
AC-3
AC-4
AC-1
3P
3 NO
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
11 kW at 400 V AC 50/60 Hz (AC-4)
18.5 kW at 220…230 V AC 50/60 Hz (AC-3)
30 kW at 380…400 V AC 50/60 Hz (AC-3)
37 kW at 500 V AC 50/60 Hz (AC-3)
37 kW at 660…690 V AC 50/60 Hz (AC-3)
40 hp at 460/480 V AC 50/60 Hz for 3 phases motors
5 hp at 115 V AC 50/60 Hz for 1 phase motors
10 hp at 230/240 V AC 50/60 Hz for 1 phase motors
20 hp at 200/208 V AC 50/60 Hz for 3 phases motors
20 hp at 230/240 V AC 50/60 Hz for 3 phases motors
50 hp at 575/600 V AC 50/60 Hz for 3 phases motors
DC standard
24 V DC
1 NO + 1 NC
6 kV conforming to IEC 60947
III
10 A (at 60 °C) for signalling circuit
80 A (at 60 °C) for power circuit
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1000 A at 440 V for power circuit conforming to IEC 60947
1000 A at 440 V for power circuit conforming to IEC 60947
520 A 40 °C – 10 s for power circuit
900 A 40 °C – 1 s for power circuit
110 A 40 °C – 10 min for power circuit
260 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
10 A gG for signalling circuit conforming to IEC 60947-5-1
125 A gG at <= 690 V coordination type 1 for power circuit
125 A gG at <= 690 V coordination type 2 for power circuit
1.5 mOhm – Ith 80 A 50 Hz for power circuit
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
0.5 Mcycles 80 A AC-1 at Ue <= 440 V
1.45 Mcycles 65 A AC-3 at Ue <= 440 V
9.6 W AC-1
6.3 W AC-3
With
Plate
Rail
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
GOST
UL
CCC
CSA
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: screw connection 1 cable(s) 1…35 mm²flexible without cable end
Power circuit: screw connection 2 cable(s) 1…25 mm²flexible without cable end
Power circuit: screw connection 1 cable(s) 1…35 mm²flexible with cable end
Power circuit: screw connection 2 cable(s) 1…25 mm²flexible with cable end
Power circuit: screw connection 1 cable(s) 1…35 mm²solid without cable end
Power circuit: screw connection 2 cable(s) 1…25 mm²solid without cable end
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 8 N.m – on EverLink BTR screw connectors – cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m – on EverLink BTR screw connectors – cable 1…25 mm² hexagonal screw head 4 mm
42.5…57.5 ms closing
16…24 ms opening
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
10 Mcycles
3600 cyc/h 60 °C
Complementary coil technology control circuit voltage limits time constant inrush power in W hold-in power consumption in W auxiliary contacts type signalling circuit frequency minimum switching current minimum switching voltage non-overlap time insulation resistance contact compatibility compatibility code motor power range motor starter type contactor coil voltage
Built-in bidirectional peak limiting diode suppressor
0.1…0.3 Uc (-40…70 °C):drop-out DC
0.75…1.25 Uc (-40…60 °C):operational DC
1…1.25 Uc (60…70 °C):operational DC
34 ms
19 W (at 20 °C)
7.4 W at 20 °C
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
25…400 Hz
5 mA for signalling circuit
17 V for signalling circuit
1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
> 10 MOhm for signalling circuit
M4
LC1D
15…25 kW at 200…240 V 3 phases
30…50 kW at 380…440 V 3 phases
30…50 kW at 480…500 V 3 phases
Direct on-line contactor
24 V DC standard
Environment IP degree of protection protective treatment pollution degree ambient air temperature for operation ambient air temperature for storage operating altitude fire resistance flame retardance mechanical robustness height width depth net weight
IP20 front face conforming to IEC 60529
TH conforming to IEC 60068-2-30
3
-40…60 °C
60…70 °C with derating
-60…80 °C
0…3000 m
850 °C conforming to IEC 60695-2-1
V1 conforming to UL 94
Vibrations contactor open: 2 Gn, 5…300 Hz
Vibrations contactor closed: 4 Gn, 5…300 Hz
Shocks contactor closed: 15 Gn for 11 ms
Shocks contactor open: 10 Gn for 11 ms
122 mm
55 mm
120 mm
0.935 kg