Please wait while your account is being registered at Tradewheel.com Loading Spinner

Join World's Fastest Growing B2B Network

Laboratory Testing Instrument Three Phase Transformer Capacity Load And No Load Tester

FOB Price 500 - 1000 USD / USD
Portchongqing, China
PackagingWooden case or custom
Lead Time7-15 days

Quick Details (View All)

Product nameno-load and load test equipment Power inputAC220V± 10%
Frequency measurement range40-65Hz, accuracy:class 0.2 Current measurement range100mA-60A,accuracy:class 0.2
Voltage measurement range10V-650V,accuracy:class 0.2 Connect external transformerYes(Broaden measure range )
Manual/autoFully-automatic RMS of three phase voltageUab,Ubc,Uca
Test methodThree meters testing methods

Product Details

Product Description

Transformer Load And No-Load Tester Short circuit loss tester

The vacuum degree tester is a vacuum degree appraisal equipment of the vacuum interrupter. It uses the magnetron discharge as the principle and the single-chip microcomputer as the main control unit. The test process is fully automated.

Introduction

GDBR-P transformer no-load tester can measure the AC voltage effective value, voltage average value, effective value, active power, power factor and frequency of three-phase power transformers. The measurement accuracy is 0.1, intelligent and professional design 3. Suitable for testing of no-load, load, induction and other tests of power transformers.

Transformer Load And No-Load Tester Short circuit loss tester.jpg

Features

  • Measure transformer no-load current, no-load loss, short-circuit voltage, short-circuit loss and capacity.
  • Three meter test method.
  • When the three-phase transformer is under no load and load test, the instrument will automatically determine whether the wiring is correct and display the three-phase voltage and current vector diagram.
  • The load test is completed at 1600kVA below the full current of a single distribution transformer. 2500kVA lower than the distribution transformer load test at 1/3 rated current (At 1/3 rated current, the instrument can be converted to load loss parameters at rated current.)
  • All test results are automatically corrected. The instrument automatically calibrates as follows, waveform correction, temperature correction, non-rated voltage correction and non-rated current correction. The test results are more accurate.
  • 320 * 240 high-brightness LCD display with brightness adjustment function. The touch button makes the operation more convenient.
  • Real-time clock, automatic recording of test date, suitable for storing and managing test results.
  • Built-in panel-type thermal printer to quickly print test results.
  • Turn off the function of storing and browsing data (test object set, measurement result, test time). Store up to 500 test results and transfer data to PC online.
  • Allows extended range of external voltage and current transformer measurements. Test object that measures any parameter.

Main technical parameters
Current measurement range: 100mA-60A,accuracy:class 0.2.
Voltage measurement range: 10V-650V,accuracy:class 0.2.
External transformer can broaden the measurement range of instrument.
Frequency measurement range: 40-65Hz, accuracy:class 0.2.
Power input: AC220V± 10%.
RMS of three phase voltage: Uab,Ubc,Uca.
Average value of three phase AC voltage: Uab,Ubc,Uca.
RMS of three phase current: Ia,Ib,Ic.
Percentage of No-load loss and No-load current: Po,Io%.
Load loss, impedance voltage percentage, short circuit impedance: Pt,ekt,Zt.
  • Load loss, impedance voltage percentage and short circuit impedance at any specified temperature.

  • Transformer actual capacity and judged capacity.

Detail image

Transformer Load Loss Test (3).jpg

Transformer Load Loss Test (3).jpg

Troubleshooting

Vacuum Degree Tester (4).jpg

Company Profile

CHONGQING GOLD MECHANICAL & ELECTRICAL EQUIPMENT CO., LTD

Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd. mainly design and manufacture the oil purifier and electrical testing equipment for more than 10 years.

After several years’ development, our products have become high intelligent and wide coverage. And our company has become one of the leading manufacturer of oil purifier and electrical testing equipment in China;

We have developed sales channels in many countries such as UAE, Saudi Arabia, Iran, Malaysia, Thailand, Pakistan, India, Germany, Belgium, USA, Mexico, Kenya, Nigeria, South Africa and other countries worldwide.

And we have gained strong advantage and high reputation in international market.

We have persisted on the business idea of "Integrity Basis and Quality First" for the stable and constant development. We are making effort to develop together with customers from both domestic and abroad on the basis of reciprocity. Client, quality and service are our supreme target!

GOLD CO,. LTD..png

Overseas Exhibition

Exhibition Abroad

Three Phase Relay Protection Tester

Feedback and Communication

Secondary Injection Tester

Shipping & Payment

Shipping & Payment.png

FAQ

1. Q: What's the delivery lead time?

A: Y"For most of the products, delivery lead time is 10 days after the order is confirmed; For some customized products, please check with the sales person."

2.Q: What's the payment term?

A: "For total amount below USD3,000.0, payment term is 100% T/T as deposit; For total amount above USD3,000.0, payment term is 30% T/T as deposit, the balance before delivery; The payment term is also negotiable."

3.Q: What's the warranty period?

A: "Warranty period is 1 year"