Please wait while your account is being registered at Tradewheel.com Loading Spinner

Join World's Fastest Growing B2B Network

KYN28-12 drawout type indoor metal-enclosed switchgear assemblies

MOQ1 set
Portningbo
Packagingwoods case
Lead Time45 days

Quick Details (View All)

rated voltage12kv,24kv,35kv

Product Details

Product overview

KYN28 drawout type indoor metal-enclosed switchgear assemblies

Rated voltage:12KV,24KV,35KV

Rated current:200A ,630A,1250A,2000A,3150A

Breaking capacity:25KA,31.5KA

KYN28 indoor metal-clad switchgear is a complete power distribution device for 3.6~24kV,3-phase AC50/60Hz,single-bus and single-bus sectionalized system. It is mainly used for power transmission of middle/small generators in power plants; power receiving, transmission for substations in power distribution and power system of factories, mines and enterprises, and starting of large high-voltage motor, etc.,so as to control, protect and monitor the system. The switchgear meets IEC298,GB3906-91.In addition to be used with domestic VS1 vacuum circuit breaker, it can also be used with VD4 from ABB, 3AH5 from Siemens domestic ZN65A, and VB2 from GE, etc.,it is truly a power distribution device with good performance.

In order to meet the requirement for wall mounting and front-end maintenance, the switchgear is equipped with a special current transformer, so that the operator can maintain and inspect it in front of the cubicle.

Service Environment

Altitude: not higher than 1000m;

Ambient temperature: upper limit +40 , lower limit -15 ,and average value is not higher than 35 in 24 hours.

Relative humidity: daily mean RH not more than 95%, monthly mean RH not more than 90%;

No obvious pollutions such as erosion or combustible gas;

No frequent violent vibrations, earthquake intensity not above 8-magnitude;

Technical parameter:

No.

Item

Unit

Data

1

Rated voltage

kV

3.6, 7.2, 12

2

Rated frequency of circuit breaker

Hz

50

3

Rated current of circuit breaker

A

630, 1250, 1600, 2000, 2500, 3150, 4000

4

Rated current of switchgear

A

630, 1250, 1600, 2000, 2500, 3150, 4000

5

Rated short -time withstandcurrent(4s)

kA

16, 20, 25, 31.5, 40, 50

6

Rated withstands current (peak)

kA

40, 50, 63, 80, 100, 25

7

Rated short -circuit breaking current

kA

16, 20, 25, 31.5, 40, 50

8

Rated short -circuit closingcurrent(peak)

kA

40, 50, 63, 80, 100, 25

9

Rated

1 min power frequency

between poles, pole to earth

kV

24, 32, 42

insulation

withstands voltage

between open contacts

kV

24, 32, 48

leve

Lightening impulse

between poles, pole to earth

kV

40, 60, 75

withstands voltage (peak)

between open contacts

kV

46, 70, 85

10

Protection level

Shell: IP4X; IP2X when the CPT

and CB doors are open

bokong electric co.,ltd

128,jingwu road ,economic development zone of yueqing

China

Get Free Quotes From Multiple Sellers

Register Your Company