JET-AG Series DC Load Bank, is also called load tester, load bank, battery capacity tester and etc. The real time on-line monitoring function offer an ability to record everything we need about battery system. Perform constant current and constant power discharging to help us know batteries’ performance exactly.
Key Functions
Ø On-line monitoring function: include pack voltage, cell voltage, pack charge/discharge current, pack charge/discharge capacity, pack monitoring time, and etc.
Ø Discharge function: constant current discharge. Discharging can be stopped by the set parameters or artificially.
Key Features:
Ø User can setup four parameters to stop discharge: pack voltage, cell voltage, discharge time, discharge capacity. It can be also stopped artificially.
Ø No need correcting voltage manually.
Ø 100 groups of on-line monitoring data and 100 groups of discharge data can be saved.
Ø It can be controlled and real-time monitored by computer via RS232, meanwhile performs pattern analysis in computer.
Ø Export data via RS232 or U disk.
Ø It cannot be started if the voltage is inconsistent.
Ø When it is abnormal, it stops testing automatically.
Ø 5.7-inch color touch TFT screen with high performance.
Ø Powerful analysis software can generate voltage/current histogram, curve chart and test report automatically.
Technical Specifications
Model |
JET-AG 48B15 |
JET-AG 48B30 |
JET-AG 110B04(08/12) |
JET-AG 220B04(08/12) |
JET-AG 380B05 |
JET-AG 600B03 |
|
Cell voltage type |
2V/6V/12V |
||||||
Cell voltage range |
2V: 0~4V; 6V: 0~8V; 12V: 0~16V |
||||||
Cell voltage resolution |
2V/6V: 0.001V; 12V: 0.01V |
||||||
Pack voltage range |
0~60V |
0~60V |
0~135V |
0~270V |
0~450V |
0~600V |
|
Pack voltage resolution |
0.01V |
||||||
Voltage testing accuracy |
0.5% |
||||||
Discharge current working range |
2~150A |
2~300A |
2~40A(80A/120A) |
2~40A(80A/120A) |
2~50A |
2~30A |
|
Constant current discharge voltage range |
42~60V |
42~60V |
90~135V |
180~270V |
340~450V |
300~600V |
|
Current resolution |
0.1A |
||||||
Current testing accuracy |
1% |
||||||
Battery capacity range |
20~1500Ah |
20~3000Ah |
20~400Ah(800/1200Ah) |
20~400Ah(800/1200Ah) |
20~500Ah |
20~800Ah |
|
Cell voltage collection method |
wire |
||||||
Working voltage |
AC220±15% |
||||||
Cooling mode |
Refrigeration by blast |
||||||
Environment |
Worked at 0℃~40℃, 20%~80%RH; Stored at -20℃~70℃ |
||||||
Comm interface |
RS232, USB |
||||||
Display |
5.7-inch touch color TFT screen |
||||||
Dimensions (mm) |
425*243*343 |
459*248*441 |
425*243*343 459*248*441 600*288*451 |
425*243*343 459*248*441 600*288*451 |
540*276*543 |
520*263*562 |
|
Weight (Kg) |
13 |
17 |
13,17,19 |
13,17,19 |
22 |
22 |
|