INR18650-3000mAh Li-ion Rechargeable cylindrical battery,18650 battery,High security lithium ion battery,power tool lithium ion battery supplier

3000mah Li-Ion Battery Product Details:

Items

Specifications

2.1 Model

INR18650-3000

2.2 Min. Capacity

2950mAhCharge: 0.5C, 4.20V,CCCV 150mA cut-off, Discharge: 0.2C, 2.5V discharge cut-off

2.3 Nominal Voltage

3.7V

2.4 Max. Charge Voltage

4.20 V

2.5 Discharge Cut-off Voltage

2.50V

2.6 Standard charge

CCCV, 1.50A, 4.20 ± 0.05 V, 150mA cut-off

2.7 Max. Charge Current

CCCV, 4A, 4.20 ± 0.05 V, 100mA cut-off

2.8 Max. Continuous Discharge Current

15 A

2.9 Max. Pulse Discharge Current

30A 2s pulse

2.10 Max. Diameter

≤18.40 mm

2.11 Max. Height

≤65.50mm

2.12 Weight

≤ 48. 0g

2.13 Impedance

≤ 18 mΩ

2.14 Operating temperature (surface temperature)

Charge: 0℃50℃

Discharge : -20℃75℃

Storage: -20℃45℃

Characteristic of Long life 18650 battery

a. Environmental conditions

Unless otherwise specified, all tests stated in this specification are conducted at temperature 23±3°and humidity under 65%.

b. Measuring equipment

(1) Amp-meter and volt-meter

The amp-meter and volt-meter should have an accuracy of the grade 0.5mA and mV or higher.

(2) Slide caliper

The slide caliper should have 0.01 mm scale.

(3) Impedance meter

The impedance meter with AC 1kHz should be used.

c. Standard charge

charging the cell CCCV with charge current 0.5C, constant voltage 4.2V and 150mA cut-off in CV mode at 23℃ for capacity.

d. Standard discharge capacity

discharge current of 600mA(0.2C) with 2.5V cut-off at 23℃within 1hour after the standard charge.

Electrical Characteristic for power tool rechargeable Li-ion battery supplier

NO.

Item

Standard

Test Method

1

Discharge rate capabilities

0.2C≥2950mAh0.5C≥2900mAh1.0C≥2850mAh3.0C≥2800mAh5.0C≥2700mAh

Standard charged, then rest for 30mins and discharge at 0.2C1C3C5 C and 2.5V cut-off

2

capacity retention and recovery

Residual capacity≥94 Recoverablecapacity≥*98

Standard charged under the condition of normal atmospheric pressure and the environmental temperature of 23℃±3℃ Stored for 28 days, then discharge at 0.2 C to 2.75V measuring residual capacity; Then standard charge/discharge measure recoverable capacity.


3

Low TemperaturePerformance

discharge capacity≥85% rated capacityno distortion and no rupture

The cell shall be charged in accordance with the standard charge. Then stored in the temperature of -10℃±1℃ for4h, Discharge at the constant current of 0.2C down to the end-of-discharge voltage 2.750V.

4

Cycle Life

1C charged the cell to 4.2V, then change to charge with constant voltage till the current less than or equal to 0.04C, rest for 30mins; 10A discharge to 2.75V, one cycle is finished, rest for 30mins. Then repeat above steps, when capacity is less than 70% of initial capacity, the battery life is over.

Safety Characteristic of car 18650 battery

NO.

Item

Standard

Test Method

1

Overcharge

No fireNo explosion

After standard charge, rest for 10mins; then charge at constant current of 3C to 10V.(or charge at 3C for90mins).

2

Forced discharge

No fireNo explosion

The battery to be discharged with standard discharging condition, Inverse charge current =1Ctime: ≥90mins


3

Short Circuit test

No fireNo explosion

The battery to be fully charged with standard charging condition, and short the positive and negative terminals with wire resistance ≤50mΩ.Tests are to be conducted at 23℃±3℃ and at 55℃ ±5℃, keep 24h or casetemperature decline to 20% of the max temperature ,test is over.

4

Crush test

No fire/No explosion

A battery is crushed between two flat surfaces. The applied force is 13 kN±1kN by hydrocylinder, Once the maximum pressure has been obtained or voltage decrease to 1/3 of nominal voltage sharply, then release pressure.

5

Shock test

No fire/No explosion

The full charged battery is fixed on shock table, to force a certain shock to three mutual vertical direction, in initial3ms, the min. average acceleration is 75gn,the peak acceleration is between 125gn and 175gn.

6

Heating test(130°C)

No fire/No explosion

The cells are fully charged with standard charging condition, and put into incubator with nature air or cycled air convected, heat battery by velocity of 5°C ±2°C/min to130°C±2°C,and maintain for 10mins.

7

TemperatureCycling Test

no leakage, no fire, no explosion

The fully charged batteries are placed in a test chamber and subjected to the following cycles: a) Raising the temperature to 75°C ±2°C within 30 minutes and maintaining this temperature for 6 hours. b) Reducing the temperature to minus 40°C ±2°C within30 minutes and maintaining this temperature for 6 hours. c) Repeating the sequence for a further 9 cycles. d) Afterthe 10th cycle, storing the batteries for 24 hours prior to examination.

Environment Adaptation Performance