Please wait while your account is being registered at Tradewheel.com Loading Spinner

Join World's Fastest Growing B2B Network

full automatic three phase transformer load and no load tester

FOB Price 1000 - 1500 USD / USD
Portchongqing, China
PackagingWooden case or custom
Lead Time7-15 days

Quick Details (View All)

Product nametransformer no load tester Power inputAC220V± 10%
Frequency measurement range40-65Hz, accuracy:class 0.2 Current measurement range100mA-60A,accuracy:class 0.2
Voltage measurement range10V-650V,accuracy:class 0.2 Connect external transformerYes(Broaden measure range )
Manual/autoFully-automatic RMS of three phase voltageUab,Ubc,Uca
Test methodThree meters testing methods Warranty1 Year

Product Details

automatic three phase transformer load tester

The vacuum degree tester is a vacuum degree appraisal equipment of the vacuum interrupter. It uses the magnetron discharge as the principle and the single-chip microcomputer as the main control unit. The test process is fully automated.

Introduction

GDBR-P transformer no-load tester can measure the AC voltage effective value, voltage average value, effective value, active power, power factor and frequency of three-phase power transformers. The measurement accuracy is 0.1, intelligent and professional design 3. Suitable for testing of no-load, load, induction and other tests of power transformers.

Transformer Load And No-Load Tester Short circuit loss tester.jpg

Features

  • Measure transformer no-load current, no-load loss, short-circuit voltage, short-circuit loss and capacity.
  • Three meter test method.
  • When the three-phase transformer is under no load and load test, the instrument will automatically determine whether the wiring is correct and display the three-phase voltage and current vector diagram.
  • The load test is completed at 1600kVA below the full current of a single distribution transformer. 2500kVA lower than the distribution transformer load test at 1/3 rated current (At 1/3 rated current, the instrument can be converted to load loss parameters at rated current.)
  • All test results are automatically corrected. The instrument automatically calibrates as follows, waveform correction, temperature correction, non-rated voltage correction and non-rated current correction. The test results are more accurate.
  • 320 * 240 high-brightness LCD display with brightness adjustment function. The touch button makes the operation more convenient.
  • Real-time clock, automatic recording of test date, suitable for storing and managing test results.
  • Built-in panel-type thermal printer to quickly print test results.
  • Turn off the function of storing and browsing data (test object set, measurement result, test time). Store up to 500 test results and transfer data to PC online.
  • Allows extended range of external voltage and current transformer measurements. Test object that measures any parameter.

Main technical parameters
Current measurement range: 100mA-60A,accuracy:class 0.2.
Voltage measurement range: 10V-650V,accuracy:class 0.2.
External transformer can broaden the measurement range of instrument.
Frequency measurement range: 40-65Hz, accuracy:class 0.2.
Power input: AC220V± 10%.
RMS of three phase voltage: Uab,Ubc,Uca.
Average value of three phase AC voltage: Uab,Ubc,Uca.
RMS of three phase current: Ia,Ib,Ic.
Percentage of No-load loss and No-load current: Po,Io%.
Load loss, impedance voltage percentage, short circuit impedance: Pt,ekt,Zt.
  • Load loss, impedance voltage percentage and short circuit impedance at any specified temperature.

  • Transformer actual capacity and judged capacity.