The LWGY series flange type liquid turbine flowmeter is the main type of velocity type flowmeter. When the measured fluid flows through the turbine flowmeter sensor, the impeller is forced to rotate under the action of the fluid, and its speed is proportional to the average flow rate of the pipeline. At the same time, the blade periodically cuts the magnetic field lines generated by the electromagnet, changing the magnetic flux of the coil. According to the principle of electromagnetic induction, a pulsating electric potential signal will be induced inside the coil, The frequency of the electrical pulse signal is proportional to the flow rate of the measured fluid.
Executive standards |
Turbine Flow Sensor (JB/T9246-1999) |
Connection method |
flange |
accuracy class |
± 1% R; ± 0.5% R; ± 0.2% R (customization required) |
Sensor material |
304, 316 stainless steel, etc |
Conditions of Use |
Medium temperature: -20 ℃~+120 ℃; Environmental temperature: -20 ℃~+60 ℃ |
Relative humidity: 5% -90%; Atmospheric pressure: 86KPa~106KPa |
|
Signal output function |
Pulse signal; 4-20mA signal |
Communication output function |
RS485 communication; HART protocol, etc |
Working power supply |
External power supply: 24VDC ± 15%, ripple ≤ ± 5%, suitable for 4-20mA output, pulse output, RS485, etc |
Internal power supply: 1 set of 3.6V10AH lithium battery, which can operate normally when the battery voltage is between 2.0-3.0V |
|
Signal line interface |
Basic type: Hausman connector or built-in three core cable; Explosion proof, internal thread M20 * 1.5 |
Explosion proof level |
Exia II CT or Exd II BT6 |
protection grade |
IP65 or higher customizable |
Room 101, Building A, Guangzheng Science and Technology Industrial Park, No.11 Nanyun Fifth Road, Huangpu District