1. MODEL ordering:IVS - HPU - A - S4005 – S
1 2 3 4 5
Tabe-1: Manufacture:IVS
Tabe-2: Product: HPU-Hydraulic Power Unit
Tabe-3: Operation code: M-manual / A-auto
Tabe-4: Model Data: S-single acting; D-double acting;
S/D4***-series, S/D5***-series, S/D7***-series (See Chart-1 )
Tabe-5:S/P/C
S: Static pressure or burst
1. Static pressure: Conduct static pressure holding testing and
record the leak volume (pressure differential)
2. Burst function: Conduct burst testing within the max. Output
pressure and record the peak pressure
3. Or combine the static pressure testing and burst testing
P: Pulse, and it is only for the single acting
pumps, frequency ≤0.5HZ,and the pulses deformation will be less
than the pump volume when the pulse pressure within the static
pressure
C: Auto calibration for pressure gauges.
Chart-1
4***series
|
|||||||||
Pump Ratio
|
Volume
|
Static pressure Kgf/cm2
|
|||||||
Single acting
|
Double acting
|
Min.
|
Max.
|
||||||
S- Volume
per Stroke /ml |
Max. Volume ml/min
|
D- Volume
per Stroke /ml |
Max. Volume ml/min
|
||||||
005
|
42
|
4200
|
84
|
8400
|
2.5
|
35
|
|||
010
|
22
|
2200
|
44
|
4400
|
5
|
70
|
|||
020
|
12
|
1200
|
24
|
2400
|
10
|
140
|
|||
030
|
7.5
|
750
|
15
|
1500
|
15
|
210
|
|||
040
|
6
|
600
|
12
|
1200
|
20
|
280
|
|||
060
|
4
|
400
|
8
|
800
|
30
|
420
|
|||
110
|
2
|
200
|
4
|
400
|
55
|
770
|
|||
155
|
1.5
|
150
|
3
|
300
|
77.5
|
1085
|
|||
240
|
1
|
100
|
2
|
200
|
120
|
1680
|
|||
300
|
0.8
|
80
|
1.6
|
160
|
150
|
2100
|
|||
5***series
|
|||||||||
Pump Ratio
|
Volume
|
Static pressure Kgf/ cm2
|
|||||||
Pump Ratio
|
Single acting
|
Double acting
|
Min.
|
Max.
|
|||||
Volume
per Stroke /ml |
Max. Volume ml/min
|
Volume
per Stroke /ml |
Max. Volume ml/min
|
||||||
005
|
90
|
9000
|
180
|
18000
|
2.5
|
35
|
|||
010
|
42
|
4200
|
84
|
8400
|
5
|
70
|
|||
012
|
36
|
3600
|
72
|
7200
|
6
|
84
|
|||
020
|
22.5
|
2250
|
45
|
4500
|
10
|
140
|
|||
025
|
16
|
1600
|
32
|
3200
|
12.5
|
175
|
|||
030
|
14
|
1400
|
28
|
2800
|
15
|
210
|
|||
035
|
12
|
1200
|
24
|
2400
|
17.5
|
245
|
|||
055
|
7.5
|
750
|
15
|
1500
|
27.5
|
385
|
|||
070
|
6
|
600
|
12
|
1200
|
35
|
490
|
|||
085
|
5
|
500
|
10
|
1000
|
42.5
|
595
|
|||
105
|
4
|
400
|
8
|
800
|
52.5
|
735
|
|||
140
|
3
|
300
|
6
|
600
|
70
|
980
|
|||
195
|
2
|
200
|
4
|
400
|
97.5
|
1365
|
|||
280
|
1.5
|
150
|
3
|
300
|
140
|
1960
|
|||
440
|
1
|
100
|
2
|
200
|
220
|
3080
|
|||
555
|
0.75
|
75
|
1.5
|
150
|
277.5
|
3885
|
|||
7***series
|
|||||||||
Pump Ratio
|
Volume
|
Static pressure Kgf/ cm2
|
|||||||
Single acting
|
Double acting
|
Min.
|
Max.
|
||||||
Volume
per Stroke /ml |
Max. Volume ml/min
|
Volume
per Stroke /ml |
Max. Volume ml/min
|
||||||
005
|
290
|
29000
|
580
|
58000
|
2.5
|
35
|
|||
010
|
146
|
14600
|
292
|
29200
|
5
|
70
|
|||
020
|
66
|
6600
|
132
|
13200
|
10
|
140
|
|||
025
|
55
|
5500
|
110
|
11000
|
12.5
|
175
|
|||
035
|
40.5
|
4050
|
81
|
8100
|
17.5
|
245
|
|||
055
|
24.5
|
2450
|
49
|
4900
|
27.5
|
385
|
|||
095
|
15
|
1500
|
30
|
3000
|
47.5
|
665
|
|||
145
|
10
|
1000
|
20
|
2000
|
72.5
|
1015
|
|||
180
|
8
|
800
|
16
|
1600
|
90
|
1260
|
|||
240
|
6
|
600
|
12
|
1200
|
120
|
1680
|
|||
330
|
4
|
400
|
8
|
800
|
165
|
2310
|
|||
460
|
3
|
300
|
6
|
600
|
230
|
3220
|
|||
740
|
2
|
200
|
4
|
400
|
370
|
5180
|
|||
NOTES: 1. S-Single acting; D-Double acting
2. The output pressure and flow rate act as reference for
order and their real valve will vary according to
pressure and driven air
|
Chart-1
2. User facility on site:
1) Air supply 7-10bar,
2) Power supply for auto type :220V 50HZ 500W,
3) Fit indoor safe area;
4) Please consult for I.P protection and hazard area,
3. Features:
1) Pressure control:≤1% F.S
2) Leak rate:≤1% of set point
3) Sampling frequency:0~1000 Hz
4. Stable Pressure:≤1% F.S
5) Inlet: Medium inlet 1/2"NPTF; Air inlet,1/2"NPTF
6) Outlet:<100MPa,3/8"NPTF ;> 100MPa, HF6
7) Relief port:3/8"NPTF
4. Material:
1) Liquid contact: tube and fitting- SS;
2) Pump material can be optional in copper alloy and SS,
3) Cabinet: Carbon steel/SS
5. Schematic:
6. Reference Profile:
Size: L600mm*W500mm*H450mm
Weight:Varys from models