Bausch & Lomb Stellaris PC
Bausch & Lomb Stellaris PC Features
The Bausch & Lomb Stellaris PC microsurgical system provides a
high-performance experience in vitreoretinal and cataract eye
surgeries. This system enables surgeons to perform different
ophthalmic procedures while saving time, space, and money for the
surgeons, and the patients. The Stellaris PC system has
light-weight, ultra high-speed vitrectomy probes for conventional
and transconjunctival vitrectomy.
Dual light source with surgeon-selected color
filters.
Optimal platform for the smallest incisions
for both retinal and cataract surgeries.
Capable of 1.8 mm MICS
phacoemulsification.
Easily upgraded to take advantage of future
technology evolutions.
19” 5:4 aspect ratio color touch screen
display.
System can be set for either gravity infusion
or infusion using pressurized air.
Bausch & Lomb Stellaris PC Specifications
Dimensions
Height: 48 in (122 cm)
Width: 18 in (45.7 cm)
Depth: 18 in (45.7 cm)
Weight: 230 lbs (114 kg)
Display
Type: Flat Panel, TFT LCD Full Color
Size: 19” (48.2 cm) Diagonal
Pixels: 1280 x 1024
Tilt: +15° up and -10° down
Swivel: ±90°
Aspiration
General: Provides Cassette Full, Near-Full and
Continuous Fluid Level Sensing. Programmable vacuum response
curves.
Modes of Operation: Linear control of vacuum.
Fixed, On/Off control of vacuum. Dual Linear Modes: Pitch or
Yaw.
Operating Parameters: I/A mode: 0 mmHg to 600
mmHg; Phaco: 10 mmHg to 600 mmHg; Vitrectomy: 0 mmHg to 600 mmHg;
Extrude: 0 mmHg to 600 mmHg; Vacuum Control: 1 mmHg
increments
Irrigation
Gravity feed from I/V bottle with pinch valve
On/Off control via footpedal
Reflux
Control: Gravity feed from I/V bottle; Modes:
Continuous, Pulsed; Activated via the Foot Control
Vitrectomy
Linear Cut Rate Mode Operating Parameters:
Range: 30 to 5000 cuts per minute in 1 cut per minute increments;
Control: Linear control of cut rate via the footpedal
Fixed Cut Rate Mode Operating Parameters:
Range: 30 to 5000 cuts per minute in 1 cut per minute increments;
Cut rate is derated no more than 20% above 3000 feet (915 meters)
altitude; Control: On/Off control of cut via the footpedal
Ultrasound Functions
Programming Levels 1,2,3
Continuous
ultrasound
Pulsed ultrasound
Fixed pulse
ultrasound
Single burst
ultrasound
Multiple burst
ultrasound
Programming Level 3 only
Dual Linear
Ultrasound
Linear Power, Linear
Pulse ultrasound
Linear Power, Linear
Duty Cycle ultrasound
Dual Linear Multiple
Burst ultrasound
Variable Power
Multiple Burst ultrasound
Variable Power Linear
Burst ultrasound
Viscous Fluid Controls
Injection Mode Pressure: 70 psi (482.6 kPa,
4.8 bar)
Extraction Mode Vacuum: Between 5 to 600 mmHg
in 10 mmHg increments
Fluid Air Exchange
Output: 0.1 micron hydrophobic filtered
air
Pressure: 150 mmHg maximum air pressure
Flow Rate: Up to 4.8 standard cubic feet per
hour (2.25 L/min)
Safety: System includes pneumatic shut-off
valve in case of power loss
Illumination
Modes of Operation: Independent Illumination
and control of either port
Lamp Type: Xenon and Xenon-Mercury
Output: Light output from a single port is
minimum 25 lumens using standard 20g probe.
Safety Filter: Both ports incorporate
permanent filtration to reduce ultraviolet, violet, deep red and
infrared light
Control: 0-100% control range, 1%
resolution
Color Filtration: None, Green, Yellow, Amber
(only available on Port 1 when a xenon lamp is installed)