Quantity | 1 - 100000 |
Price | Unit |
MOQ | 1 Unit |
Port | China |
Packaging | Custom Packaging |
Lead Time | 15-25 Days |
Energy Independence | · Seamless transition to backup mode facilitated by an integrated EMS with Advanced customization capabilities · Rapid charging or discharging capability · Improved self-consumption outcomes | Intelligent Simple O&M | · IP66-rated protection: enables outdoor installation · supportSmart l-V Curve Diagnosis Function:locate PV string faults accurately and automatically detect faults DC & AC Type ll SPD:Protect with |
Easy-to-install | · Quick and straightforward installation using basic tools · Compact wall-mount design with maximum efficiency · Pre-wired communication cables | Lead Time | 15-25 Days |
Port | China |
Am5KWI-HB-LV-SP - Amlien 5kW Single-Phase Hybrid
Inverter, Low Voltage
lnput Data (Dc) | LHHI5kW | LHHI7kW | LHHI8kW | LHHI10kW |
Max. PV Input Power | 6.5kW | 9kW | 11kW | 13.5kW |
Max PV Input Voltage | 600V | |||
Start-up Voltage | 100V | |||
Rated Voltage | 300V | 330V | 360V | 390V |
MPPT Voltage Range | 100V~550V | |||
Number of String per MPPT | 1|1 | |||
Number of MPP Trackers | 2 | |||
Max. Short Circuit Current per MPPT | 24A | |||
Max. Current per MPPT | 16A | |||
Output(EPS) | LHHI5kW | LHHI7kW | LHHI8kW | LHHI10kW |
Max.Output Power | 5.4kVA | 8kVA | 9.5kVA | 11kVA |
Max. Output Current | 20A | 20.9A | 22.7A | 27.3A |
Peak Output Power,Time | 6kW, 10s | 6.9kW, 10s | 7.5kW, 10s | 7.5kW, 10s |
Rated Voltage,Frequency | 230V, 50Hz | |||
THDv (@Rated Power) | <3% | |||
Switch Time | <10ms | |||
LHHI10kW | ||||
Output Data (Ac) | LHHI5kW | LHHI7kW | LHHI8kW | |
Rated Output Power | 5.5kVA | 8kVA | 9.5kVA | 11kVA |
Max. Output Power | 5.4kVA | 8kVA | 9.5kVA | 11kVA |
Max. Output Current | 20A | 20.9A | 22.7A | 27.3A |
Rated Voltage | 230V | |||
Rated Frequency | 50Hz/60Hz | |||
THDi(@Rated Power) | <3% | |||
Power Factor | 0.8 leading ~ 0.8 lagging | |||
General Data | LHHI5kW | LHHI7kW | LHHI8kW | LHHI10kW |
Dimension (WxH x D) | 490 x 395x 200 mm | |||
Weight | 20kg | |||
Operating Temperature Range | 30°C~+50°C | |||
Cooling Method | Natural | |||
Protection Degree | IP65 | |||
Max. Operating Altitude | 4000 m | |||
Noise | < 25dB | |||
Relative Humidity | 0~100% | |||
Self-Consumption | < 10W | |||
Battery | ||||
Battery Type | Lithium, Lead-acid | |||
Max. Charge / Discharge Current | 100A | |||
Battery Voltage Range | 40V~60V | |||
Communication | CAN | |||
Efficiency | ||||
Max. Efficiency | 0.985 | |||
Efficiency | 0.972 | |||
Battery Charge/Discharge Efficiency | 0.95 | |||
Communication | ||||
Communication | /CAN /WIFI /4G /LAN / BluetoothRS485 | |||
Display | LCD | |||
Standard Compliance | ||||
Grid Connection Standards | EC 61727,IEC 62116,IEC 60068IEC 61683.CEI 0-21VDE 0126-1-1/A1 VFR 2014 UTE C15-712-1.NRS 097-2-1.MEA/PEA.C10/11,G98/G99 | |||
Safety / EMC | IEC 62109-1,1EC 62109-2,EN 61000-6-1,EN 61000-6-3 | |||
Protection | ||||
Anti-islanding Protection | Yes | |||
DC Reverse Polarity Protection | Yes | |||
Residual Current Monitoring Unit | Yes | |||
AC short Circuit Protection | Yes | |||
Insulation Resistance Monitoring | Yes | |||
Insulation Resistance Monitoring | Yes | |||
Ground Fault Monitoring | Yes | |||
Over Current Voltage Protection | Yes | |||
Battery Soft Start Protection | Yes | |||
Surge Protection | Type Il | |||
AFCI Protection | Optional |