Quantity | 1 - 100000 |
Price | Unit |
MOQ | 1 Unit |
Port | China |
Packaging | Custom Packaging |
Lead Time | 15-25 Days |
Energy Independence | Integrated 110A MPPT solar charge · Broad PV input voltage range | Intelligent Simple O&M | Overload/overtemperature/short-circuit safeguard · Intelligent battery charger design, enhance battery performance |
Easy-to-install | Compatible with lithium battery · Up to 6 units in parallel (P model) · Multi-level charging voltages for diverse batteries · Multiple work mode, support AC priority, solar priority | Rated Power | 10kVA / 10kW |
Port | China |
Am30KWI-GT - Amlien 30kW Grid-Tied Inverter
lnput Data (Dc) | LHONG10kW | LHONG15kW | LHONG20kW | LHONG30kW | |
Max. PV Input Power | 16kW | 24kW | 32kW | 48kW | |
Max PV Input Voltage | 1100V | ||||
Start Voltage | 160V | 160V | 250V | 250V | |
Rated Input Voltage | 600V | ||||
Full-load MPP Voltage Range | 360V ~ 850V | 450V ~ 850V | 480V ~ 800V | 500V ~ 800V | |
MPPT Voltage Range | 180V ~ 1000V | 180V ~ 1000V | 200V ~ 1000V | 200V ~ 1000V | |
Number of MPP Trackers | 2 | 2 | 2 | 3 | |
Number of String per MPPT | 44958 | 44958 | 44959 | 2 | |
Max. Short Circuit Current per MPPT | 25A | 25A | 40A | 32A | |
Max. Current per MPPT | 18A | 18A | 32A | 26A | |
Output Data (Ac) | |||||
Max. Output Current | 15.9A | 23.9A | 35.3A | 48.3A | |
Rated Output Power | 10kW | 15kW | 22kW | 30kW | |
Max. Output Power | 10kW | 16.5kVA | 24.4kVA | 33.3kVA | |
Rated Grid Frequency | 50Hz / 60Hz | ||||
Rated Grid Voltage | 230Vac / 400Vac, 3L / N / PE | ||||
Power Factor | >0.99 ( 0.8 leading ~ 0.8 lagging ) | ||||
THDi | <3% ( Rated Power ) | ||||
Efficiency | |||||
Max. Efficiency | 0.986 | 0.986 | 0.984 | 0.986 | |
EU Efficiency | 0.985 | 0.985 | 0.98 | 0.985 | |
Battery Charge/Discharge Efficiency | 0.999 | ||||
Protection | |||||
Anti-islanding Protection | Yes | ||||
DC Reverse Polarity Protection | Yes | ||||
Residual Current Monitoring Unit | Yes | ||||
AC short Circuit Protection | Yes | ||||
Insulation Resistance Monitoring | Yes | ||||
Ground Fault Monitoring | Yes | ||||
Grid Monitoring | Yes | ||||
Surge Protection | Type Il | ||||
AFCI Protection | Optional | ||||
Communication | |||||
Communication | Standard:RS485 Optional:WiFi / GPRS / Etherne | ||||
Display | LED / LCD / WiFi+Appt | ||||
Standard Compliance | |||||
Grid Connection Standards |
IEC 61727, IEC 62116, IEC 60068, IEC 61683, VDE-AR-N
4105, EN 50549, AS/NZS 4777, CEI 0-21, VDE 0126-1-1/A1 VFR 2014, UTE C15-712-1, NRS 097-2-1, C10/11, G98/G998/G99 |
||||
Safety / EMC | IEC 62109-1, IEC 62109-2, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3 | ||||
General Data | |||||
Dimension (WxH x D) | 481 x 395 x 195 mm | 481 x 395 x 195 mm | 534 x 440 x 220 mm | 600 x 430 x 230 mm | |
Weight | 13.5kg | 13.5kg | 24 kg | 30 kg | |
Operating Temperature Range | -30°C~+60°C | ||||
Cooling Method | Natural | ||||
Protection Degree | IP66 | ||||
Max. Operating Altitude | 4000 m | ||||
Relative Humidity | 0 ~ 100% |