Product name30kv 40kv 50kv 60kv 70kv 80kv vlf hipot tester low frequency tester Output frequency:0.1Hz, 0.05Hz, 0.02Hz;
Measurement accuracy:2.5%; Positive and negative voltage peak error< 2.5%RDG+0.3%FS;
Voltage wave form distortion<3%; Power supply:AC220V ± 10%, 50Hz/60Hz;
WarrantyOne Year Voltage waveform distortionstortion: ≤5%

Product Details

30kv 40kv 50kv 60kv 70kv 80kv vlf hipot tester low frequency tester

VLF AC Hipot Tester Price.jpg

VLF Series 0.02Hz 30kV, 50kV, 60kV, 80kV Electric Cable Very Low Frequency VLF Hipot Tester is applied in power cable and generator insulation test in power system.

Features

  • The product combines modern advanced digital variable frequency technology and micro computer control together, therefore, it can realize the full automatic voltage boost, stepdown, measurement and protection as well as the manual intervention in the process of automatic voltage boost.
  • The full electronic design ensures the small size and light weight.
  • The big LCD screen ensures the clear and visual display, and can display the output wave form.
  • The printer can print out test reports.
  • Data of current, voltage, wave form can be directly sampled at high voltage side, so the data is real and accurate.
  • Overvoltage protection: If the output exceeds the set limit of voltage, the instrument will shut-down to protect itself, the actuation time is less than 20ms.
  • Overcurrent protection: it is high-low voltage dual protection in the design, the accurate shut-down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current, the instrument will take shut-down protection, the actuation time are both less than 20ms.
  • A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside.

Specifications

1. Output voltage ratings: See details in Table 1

2. Output frequency: 0.1Hz, 0.05Hz, 0.02Hz

3. Measurement accuracy: 3%

4. Positive and negative voltage peak errors: ≤ 3%

5. Voltage wave form distortion: ≤ 5%

6. Use condition: indoor and outdoor; temperature: -10℃-+40℃, Humidity: ≤ 85%

7. Power: AC50Hz, 220V ±5%

8. Power supply fuse tube: See Details of Table

Model

Rated Voltage/current

Load Carrying

Capacity

Power fuse wire

Product Structure and Weight

30

30kV/20mA

(Peak)

0.1Hz,≤0.5µF~1.1µF

5A

Controller:4kg

Booster: 25kg

0.05Hz,≤0.5µF~2.2µF

0.02Hz,≤0.5µF~5.5µF

50

50kV/30mA

(Peak)

0.1Hz,≤0.5µF~1.1µF

7A

Controller:4kg

Booster: 50kg

0.05Hz,≤0.5µF~2.2µF

0.02Hz,≤0.5µF~5.5µF

60

60kV/30mA

(Peak)

0.1Hz,≤0.5µF

9A

Controller:4kg

Booster Grade 1(30kV):25kg

Booster Grade 2(30kV):25kg

0.05Hz,≤0.5µF~1µF

0.02Hz,≤0.5µF~2.5µF

80

80kV/30mA

(Peak)

0.1Hz,≤0.5µF

12A

Controller:4kg

Booster Grade 1(30kV):25kg

Booster Grade 2(50kV):50kg

0.05Hz,≤0.5µF~1µF

0.02Hz,≤0.5µF~2.5µF