Port | Shanghai Port |
Packaging | Wooden Box |
Lead Time | 20-25 Working days |
Short Description:
THE Sothis class ii biosafety cabinet Type A2 provide personnel, product and environmental protection from hazardous particulates such as agents that require Biosafety Level 1, 2 or 3 containment.
APPLICATION:
THE Sothis class ii biosafety cabinet Type A2 provides personnel, product and environmental protection from hazardous particulates such as agents that require Biosafety Level 1, 2 or 3 containment. Other appropriate applications include work with antineoplastic drugs, genetic material, asbestos and additional substances that generate hazardous airborne particulates.
The Sothis class ii biosafety cabinets are designed to discharge HEPA-filtered exhaust air directly into the laboratory, or into an exhaust system through the optional Canopy Connection. When canopy-connected, the biosafety cabinets may be used for applications involving minute quantities of volatile toxic chemicals and tracer amounts of radionuclides as an adjunct to microbiological research.
During operation, room air is drawn into the inlet grill. The air in the plenum beneath the work surface is a mixture of unfiltered room air and air that has just passed through the work area. This contaminated air is drawn by the blower through the back plenum of the cabinet, where approximately 70% of the air is recirculated through the supply HEPA filter and back over the work area. The balance of the contaminated air is discharged to the environment after passing through the exhaust HEPA filter.
FEATURES:
Electronically Commutated Motor (ECM)
Noise level <63 dBA
Constant Airflow Profile (CAP) airflow monitoring system
Bright, 650Lx, glare-free LED lighting
Sothis™ Negative Pressure Channel
Supply and exhaust 99.99% efficient HEPA filters. 99.995% efficient ULPA filters available
Stainless Steel Dished Work Surface
Leak-tight stainless steel interior & powder-coated steel exterior
Fully-closing, clear 1/4" tempered safety glass sash
Nominal inflow velocity of 105 fpm (0.5 m/sec)
Nominal downflow velocity of 55 fpm (0.3 m/sec)
International electrical configurations
TECHNICAL DATASHEET SX-BHC-1000A2:
Model |
SX-BHC-1000A2 |
||
Cleanliness level |
ISO5(Class100)/ISO4(Class10) |
Filter level / filter efficiency |
HEPA/ULPA ≥99.995~99.999% @0.3μm |
Average downdraft velocity (m/s) |
0.25~0.45m/s |
Average inflow velocity (m/s) |
≥0.5m/s |
Noise |
≤65dB(A) |
Vibration peak |
≤5μm |
Power supply |
AC 220V/50Hz |
Air balance biological protection |
Personnel protection(1-8CFU/ml) (3 times repeat,5min/time) Total number of colonies in impact sampler: ≤10CFU/time total colony count : ≤5CFU/time Cross contamination protection(1-8CFU/ml) (3 times repeat, 5min/time) total colony count : ≤2CFU/time |
maximum power(KV*A) |
0.8 |
Air tightness |
Leakage ≤ 10% under 500pa pressure (within 30 minutes) |
Weight |
300Kg |
Working area W*D*H(Cm) |
100*62*62 |
Size W*D*H(CM) |
120*78*216 |
Specification and quantity of supply air filter |
1040*445*50① |
Specification and quantity of exhaust air filter) |
665*410*50① |
Specification and quantity of fluorescent lamps |
30W③ |
Specification and quantity of ultraviolet lamp |
30W① |
illumination |
650LX |
Diameter of air supply and exhaust pipe |
Φ250mm |
Wind direction |
Ejection |