Brand Name | IRXON | Model Number | IR220 infrared adapter |
Usage | LAPTOP | Output Type | AC |
Connection | Desktop | Color | Black, White |
Place of Origin | Guangdong, China | Electronics Description | infrared adapter |
Type | Serial Port Infrared Adapter |
SHENZHEN GINTECH ELECTRONIC TRADE CO., LIMITED
Jeff
Skype ID: jeffwang0110
QQ: 2860052014
Wechat: +86-13424300902
|
IR220 is a RS232 to
RAW IR (IrPHY Only) adapter, it can convert RS232 data
to infrared, no need to install driver. It features a RS232 serial cable replacement on PC or embedded system. There are 7 different default baud rates to choose when customer place an order. |
|
• Deriving power
from DTR and RTS of standard RS232 interface, user
must enable DTR and RTS before using it, or connect
DTR/RTS pin to 3.7V~12V external DC directly. |
|
|
• Connection: DB9-F
RS232 Serial COM Port • Default baud rate: 9600 bps -Default baudrate options: 2400/4800/19200/38400/57600/115200 bps • Communication Distance: 1 to 100 cm. (15°optical cone angle) • Size and weight: 2.8"L x 1.63"W x 0.68"H ( 67 x 46 x 19 mm) , 2.44oz (73g) • RS232 Cable length: 1.2m • Power Source: From DTR and RTS pin of DB9 RS232 port • Peak Power Consumption: 0.3W • Operating Temperature: -10℃ to 60℃ |
|
• IR220 RS232 Serial Port IR Adapter x 1 pcs |
|
• Serial port
setting: Please set COM port on your application program before infrared communication. For a 9600bps IR220 adapter, the serial port should be set like this: - 9600, N, 8, 1 - Flow control: none or Xon/Xoff - Enable DTR and RTS. • Changing IR220 baud rate: If you buy a standard IR220 adapter (default baud rate 9600bps), you can change its baud rate to the others by rewriting your application program source code, the following list is the program steps. 1, Open com port, clear DTR 2, Set RTS, and wait at least 7 us 3, Send Control Byte to IR220 through TXD to set new baud rate. Baud Rate Control Byte: 115200 0x00 57600 0x01 38400 0x02 19200 0x03 9600 0x04 4, Wait until the stop bit of Control Byte is sent (for 9600 baud rate, it takes about 100 ms) 5. Clear RTS (return to NORMAL operation) 6. Wait at least 50 us, new baud rate takes effect. IR220 can’t remember new baud rate set by this way, it will restore 9600bps when it is power off and restarted. Click here to download demo baud rate setting program (Need Visual Basic Runtime Library) Click here to download demo baud rate setting program source code (Visual Basic 6.0) |
|
|
2, TXD, Data from
IR220 to PC 3, RXD, Data from PC to IR220 4, DTR, Supply power (or 3.7V~12V DC-IN), select baud rate 5, GND, Ground 7, RTS, Supply power (or 3.7V~12V DC-IN), select baud rate Pin 1,6,8,9, Not Connected |