Agricultural Corn Drying Equipment(HG-500T Rice Dryer)

Product Details

Project Unit Specifications
Model Name / HG-500T Continuous Grain Dryer
Structural style / Continuous
Drying method / Indirect heating
Shape Dimension of Dryer Body (Long x Width x High) mm 5100x4160x28060
Processing capacity t/d 560
Precipitation amplitude % 10-15
Number of drying sections pcs 17
Number of alleviating Su section pcs 3
Cooling section height mm 3640
Net volume of dryer 210
Hot air temperature range 120-160
Drying capacity t%/h ≥2.4
Installation capacity kw 325.15
Grain column section size (length x width) mm 4000 x 2772
Feed throat height mm 28060
Discharge outlet height mm 860
Dryer capacity t 180
Water Inhomogeneity of Outgoing Maize / ≤1.5%(Range of tax reduction≥5%)
Value-added of maize crushing rate before and after drying / ≤0.3%
Outgoing grain temperature When the ambient temperature is higher than 0℃, it shall not exceed 8℃; when the ambient temperature is lower than 0℃, it shall not exceed 8℃.
Increased crack rate of maize before and after drying / Less than 30% (precipitation range > 10%)
Maximum grain temperature 70
Unit heat consumption of dryer kj/kgH2O 235
Waste heat recovery mode/amount kj/h 80
Ventilation Joint Thickness of Corner Box mm 2
Inner wall thickness mm 4+3
Thickness of body shell color plate mm 0.5
Life expectancy of organism year 10
Whole machine quality t 38
Number of hot air blowers 3
Driving mode / D
Type Name of Hot Air Fan / Y4-72-12C Boiler Centrifugal Induced Fan Y4-73-11C Boiler Centrifugal Induced Fan Y4-73-10C Boiler Centrifugal Induced Fan
Air pressure of hot air blower Pa 2705+2580+2359
Flow rate of hot air blower m³/h 68990+49000+44000
Hot air fan motor power kw 75+55+37
Motor Speed of Hot Fan R/min 1480+1480+1480
Type Name of Cooling Fan / 4-72-12C centrifugal fan
Motor Power of Cooling Fan kw 37
Total power of dryer motor kw 2.2+2.2
Type Name/Raw Material Type of Hot Blast Furnace / DZL-10TH light chain grate/coal and biomass
Hot Blast Furnace Power (Output Heat) kj/h(Kcal/h) 600
Type Name of Hot Blast Furnace Inducer Fan / Y5-47-10C Boiler Centrifugal Induced Draft Fan
Motor Power of Inducer Fan for Hot Blast Furnace kw 37
Type Name of Burner / RS800 Natural Gas Burner
Burner Fuel Types / Natural gas
Burner thermal power (heat output) kj/h 600